Messages Sent and Received with No-protocol Mode
Constant Cycle Time
Set the cycle time to a non-zero value, e.g., to create a consistent motor control cycle. This setting is effective
only when the actual cycle time is shorter than the constant cycle time setting. If the actual cycle time is longer
than the constant cycle time setting, the actual cycle time will remain unchanged.
Note The constant cycle time setting cannot be changed while the Module is in RUN or MONITOR mode.
Watch Cycle Time
If the cycle time exceeds the watch (maximum) cycle time setting, the Cycle Time Too Long Flag (A401.08) will
be turned ON and FQM1 operation will be stopped. This setting must be changed if the normal cycle time
exceeds the default watch cycle time setting of 50 ms.
Note The watch cycle time setting cannot be changed while the Module is in RUN or MONITOR mode.
Fixed Peripheral Servicing Time (Coordinator Module)
406
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
This setting determines whether the peripheral servicing for the following processes is performed with
the default settings or all together in a fixed servicing time.
Start code
Received bytes
Cycle Time
Too Long Flag
A401.08
Watch
Time
Yes
No
(minimum)
Constant
time
Data: 1 to 256 bytes
ST
Note The default value for the watch cycle time is 50 ms.
Actual Cycle
Watch Cycle
Data
No
Data
Time
Time
Actual Cycle
Watch Cycle
ST
Time
Time
End code
Data
Data
Yes
Watch Cycle
ED
Actual Cycle
ED
OVER
Time
Time
Module operation
is stopped.
ST
ON
Data
Data
CR+LF
CR+LF
CR+LF
Appendix C