XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 439

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
412
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
A870 to
A871
A872 to
A873
A874
A875
A876
Address
00 to 15
00 to 15
00
01
02
03
04
05
06
07
08
09 to 15
00
01
02
03
04
05
06
07
08
09 to 15
00
01
02 to 15
Bits
Pulse Output 1 PV
Note This item applies when the operation
One-shot Pulse Output 1 ON Time
Note This item applies when the operation
Pulse Time Measurement 1
Note This item applies when the operation
Pulse Output 2 PV
One-shot Pulse Output 2 ON Time
Pulse Time Measurement 2
Pulse
Output 1
Status
Pulse
Output 2
Status
Pulse
Output 1
Com-
mand
Bits
mode is relative pulse output, abso-
lute pulse output in linear mode,
absolute pulse output in circular
mode, or electronic cam mode.
mode is one-shot output mode.
mode is time measurement mode
using a pulse counter.
Pulse Output Completed Flag
Pulse Output Set Flag
Target Frequency Not Reached
Flag
Target Comparison Flag
Independent Pulse Output Flag OFF: Pulses not being output or being output contin-
PLS2 Positioning Flag
Accelerating/Decelerating Flag
Pulse Output Flag
Pulse Output Direction Flag
Reserved
Pulse Output Completed Flag
Pulse Output Set Flag
Target Frequency Not Reached
Flag
Target Comparison Flag
Independent Pulse Output Flag
PLS2 Positioning Flag
Accelerating/Decelerating Flag
Pulse Output Flag
Pulse Output Direction Flag
Reserved
PV Reset Bit
Range Comparison Results
Clear Bit
Reserved
Name
Contains the pulse output PV as an 8-digit hexadeci-
mal number.
Relative mode: 00000000 to FFFFFFFF hex
Absolute linear mode: 80000000 to 7FFFFFFF hex
Absolute circular mode: 00000000 to circular maxi-
mum count
Contains the time that the one-shot pulse output has
been ON as an 8-digit hexadecimal number.
0000 0000 to 0000 270F (unit: set by STIM(980))
Contains the time measured by the pulse counter as
an 8-digit hexadecimal number.
0000 0000 to FFFF FFFF hex (unit: set by
STIM(980))
Same as for Pulse Output 1 PV.
Same as for One-shot Pulse Output 1 ON time.
Same as for Pulse Time Measurement 1.
OFF: Pulse output not completed (OFF during pulse
output).
ON: Pulse output completed (ON when pulse distri-
bution has been completed).
OFF: Pulse output amount not set by PULS(886).
ON: Pulse output amount set by PULS(886).
OFF: Target speed has been reached during pulse
output for PLS2(887).
ON: Decelerated before reaching the target speed
during pulse output for PLS2(887).
OFF: Comparison stopped.
ON: Comparison in progress.
uously.
ON: Pulses being output.
OFF: Not positioning.
ON: Positioning in progress.
OFF: No output or constant-speed output.
ON: Acceleration or deceleration in progress for
ACC(888) or PLS2(887).
OFF: Pulse output stopped.
ON: Pulse output in progress.
OFF: CW or stopped
ON: CCW
---
Same as for Pulse Output 1 Status.
OFF: Pulse output 1 PV not reset.
ON: Resets pulse output 1 PV.
OFF: Does not clear the execution results (A880) or
output bit pattern (A881) from CTBL(882) execution
for range comparison for the pulse output PV.
ON: Clears the execution results (A880) or output bit
pattern (A881) from CTBL(882) execution for range
comparison for the pulse output PV.
---
Function
Appendix C
Module
Module
User
Controlled by