Pulse Counter Timer Specifications
7-6-9
Pulse Outputs
Target-value Comparison Interrupts from Pulse Output PVs
Note
Set the pulse output operation mode to Calculation (time measurement) in
advance in the System Setup, as shown in the following table.
An interrupt task can be executed when the pulse output PV reaches a target
value, although this function cannot be used in independent mode (position-
ing), one-shot pulse output operation mode, or electronic cam control
because the pulse output stops.
When the pulse output operation mode is set to linear mode, this function can
be used for speed control (frequency changes) based on the present position.
When the pulse output operation mode is set to circular mode, this function
can be used for continuous speed control to control a series of repetitive oper-
ations at specific positions by repeating speed control patterns.
The processing of the target-value comparison interrupts for pulse output PVs
is the same as the processing for high-speed counter PVs, so refer to Check-
ing for High-speed Counter Interrupts under High-speed Counter Function
Description in 7-5-8 Pulse Input Function Description for details.
A872
A873
Pulse Output
Timer measurement
range
Operating conditions 1. Set the pulse output operation mode to Calculation (time
Word
(1) The external pulse output from the port is disabled when this mode is se-
(2) A pulse output port that is being used as a pulse counter timer cannot be
(3) If the STIM(980) instruction is executed again to restart an operating tim-
Tab page
lected.
used for any other pulse output functions.
er, the timer value will be reset to 0 and the timer will restart.
Item
00 to 15
00 to 15
Bits
Pulse output 1
Pulse output 2
Pulse time
measurement
2
Function
0000 0000 to FFFF FFFF hex
The time units can be set to 0.01 ms, 0.1 ms, or 1 ms with the
STIM(980) instruction.
2. To start or stop the timer, execute the STIM(980) instruction
measurement) in the System Setup.
with operand C1 = #000B or #000C and one of the following
C2 values:
To start the timer, execute STIM(980) with operand C2 =
#0000.
To stop the timer, execute STIM(980) with operand C2 =
#0001.
Function
Operation mode
Operation mode
Lower
4 digits
Upper
4 digits
These words function just like the
words for pulse time measurement 1,
described above.
Specification
Calculation (time measurement)
Contents
Details
Section 7-6
233