XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 393

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
B-2-2
The following table shows the basic structure of the I/O Memory Area for the Motion Control Modules.
Note
366
I/O Memory
CIO
Area
Work Area
Auxiliary Area
TR Area
DM Area
Timer Area
Counter Area
FB Instance Area
(Timers, see note 1)
FB Instance Area
(Counters, see note 1)
Index Registers
Data Registers
I/O Area
(Built-in I/O)
Cyclic
Refresh Bit
Area
Synchronous
Data Link Bit
Area
FB Instance
Area (Non-
retained, see
note 1.)
Internal I/O
Areas
Area
(1) The FB Instance Areas (CIO 5000 to CIO 5999, T0206 to T0255, and C0206 to C0255) are set to
(2) Bits can be manipulated using TST(350), TSTN(351), SETA(530), RSTA(531), SETB(532),
(3) These DM words can be saved to flash memory by setting the Save DM Password (A752) to A5A5
Motion Control Modules
their default settings by the CX-Programmer.If function blocks are being used, the CX-Programmer
will output an error when it compiles the function if there are any instructions in the ladder program
that access words in these areas. Change the default settings with the CX-Programmer if necessary.
RSTB(533), OUTB(534).
hex and turning ON the Save DM Start Bit (A751.15).
20 bits (2
words)
600 bits
(40
words)
320 bits
(20
words)
16,000
bits
(1,000
words)
81,792
bits
(5,112
words)
4,096 bits
(256
words)
15,360
bits (960
words)
16 bits
30,000
words
2,768
words
256
words
256
words
50 bits
50 bits
16 bits
16 bits
Size
CIO 2960
to
CIO 2961
CIO 4000
to
CIO 4039
CIO 1200
to
CIO 1219
CIO 5000
to
CIO 5999
CIO 0000
to
CIO 1199
CIO 1220
to
CIO 2959
CIO 2962
to
CIO 3999
CIO 4010
to
CIO 4999
CIO 6000
to
CIO 6143
W000 to
W255
A000 to
A959
TR0 to
TR15
D00000 to
D29999
D30000 to
D32767
T0000 to
T0255
C0000 to
C0255
T0206 to
T0255
C0206 to
C0255
IR0 to IR15
DR0 to
DR15
Range
Shared
by all
tasks
usage
Task
External I/
OK
Motion
Control
Module
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
O alloca-
tion
OK
OK
OK
OK
OK
OK
OK
OK
No
No
OK
OK
OK
OK
OK
No
access
Bit
OK
OK
OK
OK
OK
OK
OK
---
OK
OK
---
---
---
---
OK
OK
access
Word
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
See
note 5.
OK
Read
Access
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
See
note 5.
OK
Write
from CX-
grammer
OK
OK
OK
OK
OK
OK
OK
No
OK
OK
OK
OK
OK
OK
No
No
Change
Pro-
Status at
Cleared
Cleared
Cleared
Cleared
Main-
tained
(See
note 3.)
Main-
tained
(See
note 4.)
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
power
ON
Appendix B
Status at
Cleared
Cleared
Main-
tained
Cleared
Main-
tained
Main-
tained
Cleared
Main-
tained
Cleared
Main-
tained
Cleared
Cleared
change
mode
OK
OK
OK
OK
OK
OK
No
No
No
No
OK
OK
OK
OK
No
No
Forc-
sta-
ing
tus
bit