XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 450

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
RS-232C Port
RS-422A Port
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
A528
A392
A619
A393
A393
A526
A318
A319
A526
Address
Address
02 to 05 RS-232C Port Error
04
05
06
07
02
00 to 15 RS-232C Port Recep-
00 to 07 RS-232C Port PT Com-
08 to 15 RS-232C Port PT Prior-
00
02 to 05 RS-422A Port Error
08
09
10
11
15
00 to 15 RS-422A Port Recep-
07
Bits
Bits
Flags
RS-232C Port Commu-
nications Error Flag
RS-232C Port Send
Ready Flag (no-protocol
mode)
RS-232C Port Recep-
tion Completed Flag
(no-protocol mode)
RS-232C Port Recep-
tion Overflow Flag (no-
protocol mode)
RS-232C Port Settings
Changing Flag
tion Counter (no-proto-
col mode)
munications Flags
ity Registered Flags
RS-232C Port Restart
Bit
Flags
RS-422A Port Commu-
nications Error Flag
RS-422A Port Send
Ready Flag (no-protocol
mode)
RS-422A Port Recep-
tion Completed Flag
(no-protocol mode)
RS-422A Port Recep-
tion Overflow Flag (no-
protocol mode)
RS-422A Port Settings
Changing Flag
tion Counter (no-proto-
col mode)
RS-422A Port Restart
Bit
Name
Name
Indicates the status of the error flags that turn ON when an error has
occurred at the RS-232C port.
Turns ON when a communications error has occurred at the RS-232C
port.
Turns ON when the RS-232C port is ready to send data in no-protocol
mode.
Turns ON when the RS-232C port has completed the reception in no-
protocol mode.
Turns ON when a data overflow occurred during reception through the
RS-232C port in no-protocol mode.
Turns ON while the RS-232C port’s communications settings are being
changed.
Indicates (in binary) the number of bytes of data received when the
RS-232C port is in no-protocol mode.
The corresponding bit will be ON when the RS-232C port is communi-
cating with a PT in NT link mode. Bits 0 to 7 correspond to units 0 to 7.
The corresponding bit will be ON for the PT that has priority when the
RS-232C port is communicating in NT link mode. Bits 0 to 7 corre-
spond to units 0 to 7.
Turn this bit ON to restart the RS-232C port.
This bit is turned OFF automatically when the restart processing is
completed.
Indicates the status the error flags that turn ON when an error has
occurred at the RS-422A port.
Turns ON when a communications error has occurred at the RS-422A
port.
Turns ON when the RS-422A port is ready to send data in no-protocol
mode.
Turns ON when the RS-422A port has completed the reception in no-
protocol mode.
Turns ON when a data overflow occurred during reception through the
RS-422A port in no-protocol mode.
Turns ON while the RS-422A port’s communications settings are being
changed.
Indicates (in binary) the number of bytes of data received when the
RS-422A port is in no-protocol mode.
Turn this bit ON to restart the RS-422A port.
This bit is turned OFF automatically when the restart processing is
completed.
Function
Function
Appendix C
Module
User
Module
User
Controlled by
Controlled by
423