XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 448

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
CPU Bus Unit Errors
Special I/O Unit Errors
Module Errors
Other
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
A410
A417
A402
A411 to
A416
A402
A418 to
A423
A402
A316
Address
Address
Address
Address
00 to 15 CPU Bus Unit Number
00 to 15 CPU Bus Unit Error,
03
07
00 to 15 Special I/O Unit Number
02
06
00 to 15 Special I/O Unit Error,
05
06
Bits
Bits
Bits
Bits
Duplication Flags
Unit Number Flags
CPU Bus Unit Setting
Error Flag
CPU Bus Unit Error
Flag
Duplication Flags
Special I/O Unit Setting
Error Flag
Special I/O Unit Error
Flag
Unit Number Flags
Motion Control Module
Monitoring Error Flag
(Coordinator Module
only)
Sync Cycle Time Too
Long Flag
Name
Name
Name
Name
The Duplication Error Flag (A401.13) and the corresponding flag in
A410 will be turned ON when an CPU Bus Unit’s unit number has
been duplicated. Bits 00 to 15 correspond to unit numbers 0 to F.
When an error occurs in a data exchange between the Coordinator
Module and a CPU Bus Unit, the CPU Bus Unit Error Flag (A402.07) is
turned ON and the bit in A417 corresponding to the unit number of the
Unit where the error occurred is turned ON. Bits 00 to 15 correspond
to unit numbers 0 to F.
ON when an installed CPU Bus Unit does not match the CPU Bus Unit
registered in the I/O table.
ON when an error occurs in a data exchange between the Coordinator
Module and a CPU Bus Unit (including an error in the CPU Bus Unit
itself).
The Duplication Error Flag (A401.13) and the corresponding flag in
A411 through A416 will be turned ON when a Special I/O Unit's unit
number has been duplicated or a Special I/O Unit’s unit number has
been set between 0 and 9. (Bits A411.00 to A416.15 correspond to
unit numbers 0 to 95.)
ON when an installed Special I/O Unit does not match the Special I/O
Unit registered in the I/O table.
This flag will be turned ON when an error occurs in a data exchange
between the Coordinator Module and a Special I/O Unit.
When an error occurs in a data exchange between the Coordinator
Module and a Special I/O Unit, the Special I/O Unit Error Flag
(A402.06) and the corresponding flag in this area are turned ON. Bits
A418.00 to A423.15 correspond to unit numbers 0 to 95.
Turns ON in the Coordinator Module when a system error, such as a
WDT error, occurs in any of the Motion Control Modules.
Turns ON when one of the Modules exceeds the specified sync cycle
time. (Coordinator Module only)
Function
Function
Function
Function
Appendix C
Module
Module
Module
Module
Controlled by
Controlled by
Controlled by
Controlled by
421