TMP92xy26AXBG Toshiba, TMP92xy26AXBG Datasheet - Page 641

no-image

TMP92xy26AXBG

Manufacturer Part Number
TMP92xy26AXBG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP92xy26AXBG

Package
FPGA228
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
144/288
Architecture
32-bit CISC
Usb/spi Channels
1/1
Uart/sio Channels
2
I2c/sio Bus Channels
1
(s)dram Controller
1
Adc 10-bit Channel
6
Da Converter
-
Timer 8-bit Channel
8
Timer 16-bit Channel
2
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
Y
Number Of I/o Ports
136
Power Supply Voltage(v)
3.0 to 3.6
1.5-V rails should be
turned on first, followed
by the 3.3-V rails.
3.25.4
PWE terminal
DVCC1A
DVCC3A
DVCC3B
DVCC1B
DVCC1C
AVCC
RESET
• Power On/Off Sequences (Initial Power ON/Complete Power OFF)
When Powering On
Note1: Although it is possible to turn on or off the 1.5-V and 3.3-V power supply rails simultaneously, it may cause
Note2: In the power-on sequence, the 3.3-V power supply rails must not be turned on before the ones of 1.5-V. In the
circuit blocks first and then to the external circuit blocks. Also, in the complete power-off
sequence, power must be removed from the external circuit blocks and then from the
on-chip circuit blocks.
Notes on Power-On/Off Sequences
As shown below, in the initial power-on sequence, power must be supplied to the on-chip
external pins to temporarily become unstable. Therefore, if there is any possibility that this would affect
peripheral devices connected with the TMP92CF26A, external power supplies should be turned on or off while
the internal power supplies are stable, as indicated by the heavy lines in the diagram above.
power-off sequence, the 3.3-V power supply rails must not be turned off after the ones of 1.5-V.
Power-on
(DVCC1A, DVCC1B, DVCC1C) → (DVCC3A, DVCC3B, AVCC)
Power-off
(AVCC, DVCC3A, DVCC3B) → (DVCC1C, DVCC1B, DVCC1A)
Power should rise and stabilize
within 100 ms.
High-frequency Oscillation Stabilizing Time
+20 system clock cycles
92CF26A-639
Power Cut Mode (PMC)
Power should fall and stabilize
within 100 ms.
When Powering Off
3.3-V rails should be turned
off first, followed by the 1.5-V
rails.
TMP92CF26A
2009-06-25

Related parts for TMP92xy26AXBG