TMP92xy26AXBG Toshiba, TMP92xy26AXBG Datasheet - Page 622

no-image

TMP92xy26AXBG

Manufacturer Part Number
TMP92xy26AXBG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP92xy26AXBG

Package
FPGA228
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
144/288
Architecture
32-bit CISC
Usb/spi Channels
1/1
Uart/sio Channels
2
I2c/sio Bus Channels
1
(s)dram Controller
1
Adc 10-bit Channel
6
Da Converter
-
Timer 8-bit Channel
8
Timer 16-bit Channel
2
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
Y
Number Of I/o Ports
136
Power Supply Voltage(v)
3.0 to 3.6
3.23.2.3 Starting an AD Conversion
Note: If changing HTSEL at HHTRGE is “ON”, maybe unexpected interrupts occurs. If changing HTSEL, once set
HHTRGE to “OFF”.
conversion.
Top-priority
ADMOD2<HADS> to “1.”
operation modes specified by ADMOD1<REPEAT, SCAN>. The operation mode for
top-priority AD conversion is only single conversion by channel-fix mode.
Top-priority AD conversion. The ADC initiates a normal AD conversion by software
when the ADMOD0<ADS> is set to “1”. It initiates a Top-priority AD conversion by
software when the ADMOD2<HADS> is set to “1”. For a normal AD conversion,
ADMOD1<REPEAT, SCAN> select one of four conversion modes. For a Top-priority
AD conversion, the ADC only supports Fixed-Channel Single Conversion mode.
a normal and Top-priority AD conversion, respectively. When these bits are set to “10”,
a normal or Top-priority AD conversion is triggered by a falling edge applied to
pin. When ADMOD0<TSEL1:0> is set to “00”, a normal AD conversion is triggered by
INTTB00 of 16-Bit Timer interrupt. When ADMOD2<HTSEL1:0> is set to “00”, a
Top-priority AD conversion is triggered by INTTB10 of 16-Bit Timer interrupt. If this
bit is “11”, it is triggered by I2S sampling block. Even when a hardware trigger is
enabled, software starting can be used.
(ADMOD0<BUSY>) that shows the state for AD being converted is set to “1.”
(ADMOD2<HBUSY>) that shows the state for AD being converted is set to “1.”
ADMOD0<BUSY> is kept to “1.”
The AD conversion has the two types of normal AD conversion and top-priority AD
Normal AD conversion can be started up by setting ADMOD0<ADS> to “1.”
For normal AD conversion, one operation mode is selected from the four types of
The ADC supports two types of AD conversion: normal AD conversion and
The ADMOD0<TSEL1:0> and ADMOD2<HTSEL1:0> enable a hardware trigger for
When top-priority AD conversion is started, the AD conversion BUSY flag
In addition, when top-priority conversion is started during normal AD conversion,
When normal AD conversion is started, the AD conversion BUSY flag
AD
conversion
92CF26A-620
can
be
started
up
by
software
TMP92CF26A
2009-06-25
by
setting
ADTRG

Related parts for TMP92xy26AXBG