TMP91xy25FG Toshiba, TMP91xy25FG Datasheet - Page 172

no-image

TMP91xy25FG

Manufacturer Part Number
TMP91xy25FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP91xy25FG

Package
LQFP100
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
Ramless
Architecture
16-bit CISC
Usb/spi Channels
-
Uart/sio Channels
2
I2c/sio Bus Channels
-
(s)dram Controller
-
Adc 10-bit Channel
4
Da Converter
-
Timer 8-bit Channel
4
Timer 16-bit Channel
-
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
Y
Number Of I/o Ports
49
Power Supply Voltage(v)
3.0 to 3.6
Table 3.11.2 Relationship between AD Conversion Modes and Interrupt Requests
X: Don’t care
Channel fixed repeat
Channel scan repeat
Channel fixed single
Channel scan single
conversion mode
conversion mode
conversion mode
conversion mode
(d) Channel scan repeat conversion mode
Mode
Setting ADMOD0<REPEAT> and ADMOD0<SCAN> to 11 selects channel scan
repeat conversion mode.
In this mode, data on the specified scan channels is converted repeatedly. When
each scan conversion has been completed, ADMOD0<EOCF> is set to 1 and an
INTAD interrupt request is generated. ADMOD0<ADBF> is not cleared to 0 but
held 1.
To stop conversion in a repeat conversion mode (e.g., in cases (C) and (d)), write 0 to
ADMOD0<REPEAT>. After the current conversion has been completed, the repeat
conversion mode terminates and ADMOD0<ADBF> is cleared to 0.
Switching to a halt state (IDLE2 mode with ADMOD1<I2AD> cleared to 0, IDLE1
mode or STOP mode) immediately stops operation of the AD converter even when
AD conversion is still in progress. In repeat conversion modes (e.g., in cases (C) and
(d)), when the halt is released, conversion restarts from the beginning. In single
conversion modes (e.g., in cases (a) and (b)), conversion does not restart when the
halt is released (the converter remains stopped).
Table 3.11.2 shows the relationship between the AD conversion modes and
interrupt requests.
After completion of scan
Every forth conversion
every scan conversion
Interrupt Request
After completion of
After completion of
Every conversion
Generation
conversion
conversion
91C025-170
<ITM0>
X
X
0
1
X
<REPEAT>
ADMOD0
0
0
1
1
<SCAN>
0
1
0
1
TMP91C025