TMP91xy25FG Toshiba, TMP91xy25FG Datasheet - Page 171

no-image

TMP91xy25FG

Manufacturer Part Number
TMP91xy25FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP91xy25FG

Package
LQFP100
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
Ramless
Architecture
16-bit CISC
Usb/spi Channels
-
Uart/sio Channels
2
I2c/sio Bus Channels
-
(s)dram Controller
-
Adc 10-bit Channel
4
Da Converter
-
Timer 8-bit Channel
4
Timer 16-bit Channel
-
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
Y
Number Of I/o Ports
49
Power Supply Voltage(v)
3.0 to 3.6
(3) Starting AD conversion
(4) AD conversion modes and the AD conversion end interrupt
ADMOD1<ADTRGE> in AD mode control register 1 and input falling edge on
pin. When AD conversion starts, the AD conversion busy flag ADMOD0<ADBF> will
be set to 1, indicating that AD conversion is in progress.
time, to determine whether the AD conversion results have been preserved, check the
value of the conversion data storage flag ADREGxL<ADRxRF>.
register 0 determine the AD mode setting.
request. Also, ADMOD0<EOCF> will be set to 1 to indicate that AD conversion has
been completed.
(a) Channel fixed single conversion mode
(b) Channel scan single conversion mode
(c) Channel fixed repeat conversion mode
To start AD conversion, write 1 to ADMOD0<ADS> in AD mode control register 0, or
Writing 1 to ADMOD0<ADS> during AD conversion restarts conversion. At that
During AD conversion, a falling edge input on the
The 4 AD conversion modes are:
The ADMOD0<REPEAT> and ADMOD0<SCAN> settings in AD mode control
Completion of AD conversion triggers an INTAD AD conversion end interrupt
Setting ADMOD0<REPEAT> and ADMOD0<SCAN> to 00 selects channel fixed
single conversion mode.
In this mode, data on one specified channel is converted once only. When the
conversion has been completed, the ADMOD0<EOCF> flag is set to 1, ADMOD0
<ADBF> is cleared to 0, and an INTAD interrupt request is generated.
Setting ADMOD0<REPEAT> and ADMOD0<SCAN> to 01 selects channel scan
single conversion mode.
In this mode, data on the specified scan channels is converted once only. When
scan
ADMOD0<ADBF> is cleared to 0, and an INTAD interrupt request is generated.
Setting ADMOD0<REPEAT> and ADMOD0<SCAN> to 10 selects channel fixed
repeat conversion mode.
In this mode, data on one specified channel is converted repeatedly. When
conversion
ADMOD0<ADBF> is not cleared to 0 but held 1. INTAD interrupt request
generation timing is determined by the setting of ADMOD0<ITM0>.
Setting <ITM0> to 0 generates an interrupt request every time an AD conversion
is completed.
Setting <ITM0> to 1 generates an interrupt request on completion of every fourth
conversion.
Channel fixed single conversion mode
Channel scan single conversion mode
Channel fixed repeat conversion mode
Channel scan repeat conversion mode
conversion
has
been
has
91C025-169
been
completed,
completed,
ADMOD0<EOCF>
ADMOD0<EOCF>
ADTRG
pin will be ignored.
is
set
is
TMP91C025
2007-02-28
to
set
ADTRG
1
to
and
1,

Related parts for TMP91xy25FG