MPC8544DS Freescale Semiconductor, MPC8544DS Datasheet - Page 511

BOARD DEVELOPMENT SYSTEM 8544

MPC8544DS

Manufacturer Part Number
MPC8544DS
Description
BOARD DEVELOPMENT SYSTEM 8544
Manufacturer
Freescale Semiconductor
Series
PowerQUICC III™r
Type
MPUr
Datasheets

Specifications of MPC8544DS

Contents
Board
Processor To Be Evaluated
MPC8544E
Data Bus Width
32 bit
Interface Type
Ethernet, I2C
Operating Supply Voltage
- 0.3 V to + 1.1 V
Leaded Process Compatible
Yes
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
For Use With/related Products
MPC8544
For Use With
PPC8544EVTANG - EVAL MPC8544 783FCPBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 12-13
12.4.1.8
The PKEU interrupt control register controls the result of detected errors. For a given error (as defined in
Section 12.4.1.7, “PKEU Interrupt Status Register
is set, then the error is disabled; no error interrupt occurs and the interrupt status register is not updated to
reflect the error. If the corresponding bit is not set, then upon detection of an error, the PKEU interrupt
status register is updated to reflect the error, causing assertion of the error interrupt signal, and causing the
module to halt processing.
Freescale Semiconductor
58–63
0–49
Bits
50
51
52
53
54
55
56
57
Name
DSE
INV
KSE Key size error. Value outside the bounds of 1–256 bytes was written to the PKEU key size register
CE
ME
AE
IE
describes PKEU interrupt status register fields.
PKEU Interrupt Control Register (PKEUICR)
Reserved
Inversion error. Indicates that the inversion routine has a zero operand.
0 No inversion error detected
1 Inversion error detected
Internal error. An internal processing error was detected while the PKEU was operating.
0 No error detected
1 Internal error
Note: This bit will be asserted any time an enabled error condition occurs and can only be cleared by setting
Reserved
Context error. A PKEU key register, the key size register, the data size register, or mode register was modified
while the PKEU was operating.
0 No error detected
1 Context error
0 No error detected
1 Key size error detected
Data size error. Value outside the bounds 97– 2048 bits was written to the PKEU data size register
0 No error detected
1 Data size error detected
Mode error. An illegal value was detected in the mode register.
0 No error detected
1 Mode error
Note: Writing to reserved bits in a mode register is a likely source of error.
Address error. Illegal read or write address was detected within the PKEU address space.
0 No error detected
1 Address error
Reserved
MPC8544E PowerQUICC III Integrated Host Processor Family Reference Manual, Rev. 1
the corresponding bit in the interrupt control register or by resetting the PKEU.
Table 12-13. PKEU interrupt Status Register Field Descriptions
(PKEUISR)”), if the corresponding bit in this register
Description
Security Engine (SEC) 2.1
12-31