PSB21473FV13XT Infineon Technologies, PSB21473FV13XT Datasheet - Page 301

no-image

PSB21473FV13XT

Manufacturer Part Number
PSB21473FV13XT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of PSB21473FV13XT

Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
3.135V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
144
Lead Free Status / RoHS Status
Compliant
INCA-D
PSB 21473
IOM-2 Handler, TIC/CI Handler and HDLC Controller
17.3.3.2 Possible Error Conditions during Reception of Frames
If parts of a frame get lost because the receive FIFO is full, the Receive Data Overflow
(RDO) bit in the RSTA byte will be set. If a complete frame is lost, i.e. if the FIFO is full
when a new frame is received, the receiver will assert a Receive Frame Overflow (RFO)
interrupt.
The microcontroller sees a cyclic buffer, i.e. if it tries to read more data than available, it
reads the same data block again and again. On the other hand, if it doesn’t read all data,
they are deleted after the RMC command.
If the microcontroller reads data without a prior RME or RPF interrupt, the content of the
RFIFO would not be corrupted, but new data is only transferred to the host as long as
new valid data is available in the RFIFO, otherwise the last data is read again and again.
17.3.3.3 Data Reception Procedure
The general procedures for a data reception sequence are outlined in the flow diagram
in figure 17-18.
Data Sheet
301
2003-03-31

Related parts for PSB21473FV13XT