Specifications of TMP92xy21FG

Package
LQFP144
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
16
Architecture
32-bit CISC
Usb/spi Channels
-
Uart/sio Channels
2
I2c/sio Bus Channels
-
(s)dram Controller
1
Adc 10-bit Channel
4
Da Converter
-
Timer 8-bit Channel
4
Timer 16-bit Channel
1
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
Y
Number Of I/o Ports
82
Power Supply Voltage(v)
3.0 to 3.6
(3) Starting AD conversion
(4) AD conversion modes and the AD conversion end interrupt
or ADMOD2<ADTRGE> in AD mode control register 2, and input falling edge on
ADMOD0<ADBF> will be set to 1, indicating that AD conversion is in progress.
register 0 determine the AD mode setting.
request. Also, ADMOD0<EOCF> will be set to 1 to indicate that AD conversion has
been completed.
ADTRG
1.
2.
To start AD conversion, write a 1 to ADMOD0<ADS> in AD mode control register “0”
During AD conversion, a falling edge input on the
The four AD conversion modes are:
The ADMOD0<REPEAT> and ADMOD0<SCAN> settings in AD mode control
Completion of AD conversion triggers an INTAD AD conversion end interrupt
Channel fixed single conversion mode
channel fixed single conversion mode.
conversion has been completed, the ADMOD0<EOCF> flag is set to 1,
ADMOD0<ADBF> is cleared to 0, and an INTAD interrupt request is generated.
Channel scan single conversion mode
channel scan single conversion mode.
scan conversion has been completed, ADMOD0<EOCF> is set to 1,
ADMOD0<ADBF> is cleared to 0, and an INTAD interrupt request is generated.
Channel fixed single conversion mode
Channel scan single conversion mode
Channel fixed repeat conversion mode
Channel scan repeat conversion mode
Setting ADMOD0<REPEAT> and ADMOD0<SCAN> to 00 selects conversion
In this mode, data on one specified channel is converted once only. When the
Setting ADMOD0<REPEAT> and ADMOD0<SCAN> to 01 selects conversion
In this mode, data on the specified scan channels is converted once only. When
pin.
When AD
92CH21-310
conversion
starts,
the
ADTRG
AD conversion busy
pin will be ignored.
TMP92CH21
2009-06-19
flag