TMP92xy21FG Toshiba, TMP92xy21FG Datasheet - Page 244

no-image

TMP92xy21FG

Manufacturer Part Number
TMP92xy21FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP92xy21FG

Package
LQFP144
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
16
Architecture
32-bit CISC
Usb/spi Channels
-
Uart/sio Channels
2
I2c/sio Bus Channels
-
(s)dram Controller
1
Adc 10-bit Channel
4
Da Converter
-
Timer 8-bit Channel
4
Timer 16-bit Channel
1
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
Y
Number Of I/o Ports
82
Power Supply Voltage(v)
3.0 to 3.6
bmRequestType
110000xxB
(3) Vendor request (Class request)
request is stored, and identify the request. If this request is a Vendor request,
control the UDC externally, and process the Vendor request.
read), and for the case where data phase is receiving (Control write).
(a) Control request
UDC does not support “Automatic answer” of Vendor requests.
According to INT_SETUP interrupt, access the register in which the device
Below is an explanation for the case where data phase is transmitting (Control
bmRequestType, bRequest, wValue, wIndex and wLength registers and
process each request. According to application, access Setup_Received register
after request has been identified. UDC must also be informed that
INT_SETUP interrupt has been recognized.
and confirm EP0_DSET_A bit is “0”. After confirming, write data FIFO of
endpoint 0. If transmitting data is more than payload, write data after it
confirming whether EP0_DSET_A bit in DATASET register is “0”.
(INT_ENDPOINT0 interrupt can be used.) If writing all data is finished, write
“0” to EP0 bit of EOP register. When UDC receives this, the status stage
finishes automatically.
normally. If finishing status stage normally is recognized by external
application, manage this stage by using this interrupt signal. If status stage
cannot be finished normally and during status stage, a new SETUP token may
be received. In this case, when INT_SETUP interrupt signal is asserted, “1” is
set to STAGE_ERROR bit of EP0_STATUS register informing externally that
the status stage cannot be finished normally.
the value showed to wLength by protocol of control read transfer type in USB.
If the application program is configured using only the wLength value,
processing cannot be carried out when the host shifts status stage without
arriving at the expected data number. At this point, shifting to status stage
can be confirmed by using INT_STATUSNAK interrupt signal. (However,
releasing mask of STATUS_NAK bit by using interrupt control register is
needed.) In Vendor Request, this problem will not occur because the receiving
buffer size is set to host controller by driver. (In every host, data (data that is
transmitted from device by payload of 8 bytes) may be taken to be short packet
until confirmation of payload size on device side. Therefore, exercise care if
controlling standard requests by software.)
When
After transmitting data prepared in application, access DATASET register,
INT_STATUS interrupt is asserted when UDC finishes status stage
Vendor specific
The dataphase may have finished on a data number that is shorter than
bRequest
INT_SETUP is received,
Vendor specific
92CH21-242
wValue
Vendor specific
wIndex
identify
Vendor specific
wLength
(Expire 0)
contents
of request
TMP92CH21
Vendor data
2009-06-19
Data
by