tmp19a44fda TOSHIBA Semiconductor CORPORATION, tmp19a44fda Datasheet - Page 580

no-image

tmp19a44fda

Manufacturer Part Number
tmp19a44fda
Description
32bit Tx System Risc
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmp19a44fdaXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp19a44fdaXBG 040A
Manufacturer:
TOSHIBA
Quantity:
12 087
Part Number:
tmp19a44fdaXBG 041A
Manufacturer:
TOSHIBA
Quantity:
16 800
Part Number:
tmp19a44fdaXBG 7GR3
Manufacturer:
TOSHIBA
Quantity:
25 031
Part Number:
tmp19a44fdaXBG 7H36
Manufacturer:
SMD
Quantity:
3 200
Part Number:
tmp19a44fdaXBG7NG8
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp19a44fdaXBG7PA2
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
JTAG Interface
The TAP controller operates in each state described below. In Fig. 23-7, a column to the left is the data
column and a column to the right is the instruction column. The data column represents the data register
(DR), and the instruction column represents the instruction register (IR).
Test-Logic-Reset
If the TAP controller is in a reset state, the device identification register is selected by default. The
most significant bit in the boundary scan register is cleared to "0," and the output is disabled.
The TAP controller remains in the Test-Logic-Reset state if TMS is "1." If "0" is input into TMS
in the Test-Logic-Reset state, the TAP controller goes into the Run-Test/Idle state.
Run-Test/Idle
In the Run-Test/Idle state, the IC goes into test mode only if a specific instruction, such as the
built-in self test (BIST) instruction, is issued. If an instruction that cannot be executed in the Run-
Test/Idle state has been issued, the test data register selected by the last instruction maintains the
existing state.
The TAP controller remains in the Run-Test/Idle state if TMS is "0." If "1" is input into TMS, the
TAP controller goes into the Select-DR-Scan state.
Select-DR-Scan
The Select-DR-Scan state of the TAP controller is a transient state. In this state, the IC performs
no operations. If "0" is input into TMS when the TAP controller is in the Select-DR-Scan state,
the TAP controller goes into the Capture-DR state. If "1" is input into TMS, the instruction
column goes into the Select-IR-Scan state.
Select-IR-Scan
The Select-IR-Scan state of the TAP controller is a transient state. In this state, the IC performs no
operations.
If "0" is input into TMS when the TAP controller is in the Select-IR-Scan state, the TAP controller
goes into the Capture-IR state. If "1" is input into TMS, the TAP controller returns to the Test-
Logic-Reset state.
Capture-DR
If the data register selected by the instruction register has parallel inputs when the TAP controller
is in the Capture-DR state, data is loaded into the data register in a parallel fashion. If the data
register does not have parallel inputs or if data does not need to be loaded into the selected test
data register, the data register maintains the existing state.
If "0" is input into TMS when the TAP controller is in the Capture-DR state, the TAP controller
goes into the Shift-DR state. If "1" is input into TMS, the TAP controller goes into the Exit 1-DR
state.
TMP19A44(rev1.3) 23-8
TMP19A44
2010-04-01

Related parts for tmp19a44fda