tmp19a44fda TOSHIBA Semiconductor CORPORATION, tmp19a44fda Datasheet - Page 390

no-image

tmp19a44fda

Manufacturer Part Number
tmp19a44fda
Description
32bit Tx System Risc
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmp19a44fdaXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp19a44fdaXBG 040A
Manufacturer:
TOSHIBA
Quantity:
12 087
Part Number:
tmp19a44fdaXBG 041A
Manufacturer:
TOSHIBA
Quantity:
16 800
Part Number:
tmp19a44fdaXBG 7GR3
Manufacturer:
TOSHIBA
Quantity:
25 031
Part Number:
tmp19a44fdaXBG 7H36
Manufacturer:
SMD
Quantity:
3 200
Part Number:
tmp19a44fdaXBG7NG8
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp19a44fdaXBG7PA2
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Serial Channel (SIO)
(1) Input clock
(2) UART mode
14.4.2.2
The baud rate generator uses one of four clocks ( φ T1, φ T4, φ T16 or φ T64) supplied from the prescaler
output clock. This input clock selection is made by setting the baud rate generator control register, BR0CR
<BR0CK1:0>.
Specify the divide ratio of the output clock with the baud rate generator control register
BR0CR<BR0ADDE><BR0S3:0> and the baud rate generator control register 2 BR0ADD<BR0K3:0>.
The baud rate generator divides clocks input from prescaler, and generates transmit and receive clocks.
Baud Rate Generator
BR0CR<BR0ADDE>
N+
(16 −
16
K)
“0”
“1”
division
TMP19A44(rev1.3) 14-38
Table 14.9 UART mode
BR0ADD<BR0K3:0>
(K=1,2,3…15)
Set divide ratio “K”
Setting invalid
Setting valid
BR0CR<BR0S3:0>
Set divide ratio “N”
Set divide ratio “N”
(N=1,2,3…16)
(N=2,3…15)
N=1,16: setting
Setting valid
Setting valid
prohibited
TMP19A44
2010-04-01