tmp19a44fda TOSHIBA Semiconductor CORPORATION, tmp19a44fda Datasheet - Page 370

no-image

tmp19a44fda

Manufacturer Part Number
tmp19a44fda
Description
32bit Tx System Risc
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmp19a44fdaXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp19a44fdaXBG 040A
Manufacturer:
TOSHIBA
Quantity:
12 087
Part Number:
tmp19a44fdaXBG 041A
Manufacturer:
TOSHIBA
Quantity:
16 800
Part Number:
tmp19a44fdaXBG 7GR3
Manufacturer:
TOSHIBA
Quantity:
25 031
Part Number:
tmp19a44fdaXBG 7H36
Manufacturer:
SMD
Quantity:
3 200
Part Number:
tmp19a44fdaXBG7NG8
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp19a44fdaXBG7PA2
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
14.2.15 Direction of Data Transfer
14.2.16 Stop Bit Length
14.2.17 Status Flag
14.2.18 Configurations of Send/Receive Buffers
Serial Channel (SIO)
In the I/O interface mode, the direction of data transfer can be switched between "MSB first" and "LSB
first" by the data transfer direction setting bit <DRCHG> of the SC0MOD2 serial mode control register
2. Don't switch the direction when data is being transferred.
In the UART mode transmission, the stop bit length can be set to either 1 or 2 bits by bit 4 <SBLEN> of
the SC0MOD2 register.
If the double buffer function is enabled (SC0MOD2 <WBUF> = "1"), the bit 6 flag <RBFLL> of the
SC0MOD2 register indicates the condition of receive buffer full. When one frame of data has been
received and transferred from buffer 1 to buffer 2, this bit is set to "1" to show that buffer 2 is full (data
is stored in buffer 2). When the receive buffer is read by CPU/DMAC, it is cleared to "0." If <WBUF>
is set to "0," this bit is insignificant and must not be used as a status flag. When double buffering is
enabled (SC0MOD2 <WBUF> = "1"), the bit 7 flag <TBEMP> of the SC0MOD2 register indicates that
send buffer 2 is empty. When data is moved from send buffer 2 to send buffer 1 (shift register), this bit
is set to "1" indicating that send buffer 2 is now empty. When data is set to the send buffer by
CPU/DMAC, the bit is cleared to "0." If <WBUF> is set to "0," this bit is insignificant and must not be
used as a status flag.
3.
(SCLK output)
Framing error <FERR>: Bit 2 of the SC0CR register
In the UART mode, this bit is set to "1" when a framing error is generated. This flag is set to
"0" when it is read. A framing error is generated if the corresponding stop bit is determined to
be "0" by sampling the bit at around the center. Regardless of the <SBLEN> (stop bit length)
setting of the serial mode control register 2, SC0MOD2, the stop bit status is determined by
only 1 bit on the receive side.
(SCLK input)
I/O interface
I/O interface
Operation mode
UART
I/O interface
(SCLK input)
I/O interface
(SCLK output)
UART
TMP19A44(rev1.3) 14-18
Transmit buffer
Transmit buffer
Transmit buffer
Receive buffer
Receive buffer
Receive buffer
Error flag
OERR
PERR
FERR
OERR
PERR
FERR
OERR
PERR
FERR
<WBUF> = 0
Function
Overrun error flag
Parity error flag
Framing error flag
Overrun error flag
Underrun error flag (WBUF = 1)
Fixed to 0 (WBUF = 0)
Fixed to 0
Operation undefined
Operation undefined
Fixed to 0
Double
Double
Single
Single
Single
Single
<WBUF> = 1
Double
Double
Double
Double
Double
Double
TMP19A44
2010-04-01

Related parts for tmp19a44fda