D6417729RHF200BV Renesas Electronics America, D6417729RHF200BV Datasheet - Page 81

IC SUPER H MPU ROMLESS 208QFP

D6417729RHF200BV

Manufacturer Part Number
D6417729RHF200BV
Description
IC SUPER H MPU ROMLESS 208QFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of D6417729RHF200BV

Core Processor
SH-3 DSP
Core Size
32-Bit
Speed
200MHz
Connectivity
EBI/EMI, FIFO, IrDA, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
96
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.85 V ~ 2.15 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
208-QFP Exposed Pad, 208-eQFP, 208-HQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D6417729RHF200BV
Manufacturer:
EVERLIGHT
Quantity:
1 000
Part Number:
D6417729RHF200BV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Table 2.5
Bits
31–8
7
6
5
4
3–1
0
DSR Register Bits
Name (Abbreviation)
Reserved bits
Signed Greater Than bit
(GT)
Zero bit (Z)
Negative bit (N)
Overflow bit (V)
Condition Select bits (CS) Designate the mode for selecting the operation result
DSP Condition bit (DC)
Function
0: Always read as 0; always use 0 as the write value
Indicates that the operation result is positive (except
0), or that operand 1 is greater than operand 2
1: Operation result is positive, or operand 1 is greater
Indicates that the operation result is zero (0), or that
operand 1 is equal to operand 2
1: Operation result is zero (0), or operand 1 is equal
Indicates that the operation result is negative, or that
operand 1 is smaller than operand 2
1: Operation result is negative, or operand 1 is
Indicates that the operation result has overflowed
1: Operation result has overflowed
status to be set in the DC bit
Do not set these bits to 110 or 111
000: Carry/borrow mode
001: Negative value mode
010: Zero mode
011: Overflow mode
100: Signed greater mode
101: Signed greater than or equal to mode
Sets the status of the operation result in the mode
designated by the CS bits
0: Designated mode status has not occurred (false)
1: Designated mode status has occurred
than operand 2
to operand 2
smaller than operand 2
Rev. 5.0, 09/03, page 33 of 806