IC ARM CORTEX MCU 512K 100-LQFP

LPC1769FBD100,551

Manufacturer Part Number
LPC1769FBD100,551
Description
IC ARM CORTEX MCU 512K 100-LQFP
Manufacturer
NXP Semiconductors
Series
LPC17xxr

Specifications of LPC1769FBD100,551

Program Memory Type
FLASH
Program Memory Size
512KB (512K x 8)
Package / Case
100-LQFP
Core Processor
ARM® Cortex-M3™
Core Size
32-Bit
Speed
120MHz
Connectivity
CAN, Ethernet, I²C, IrDA, Microwire, SPI, SSI, UART/USART, USB OTG
Peripherals
Brown-out Detect/Reset, DMA, I²S, Motor Control PWM, POR, PWM, WDT
Number Of I /o
70
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
2.4 V ~ 3.6 V
Data Converters
A/D 8x12b, D/A 1x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
LPC17
Core
ARM Cortex M3
Data Bus Width
32 bit
Data Ram Size
64 KB
Interface Type
Ethernet, USB, OTG, CAN
Maximum Clock Frequency
120 MHz
Number Of Programmable I/os
70
Number Of Timers
4
Operating Supply Voltage
3.3 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2, MCB1760, MCB1760U, MCB1760UME
Minimum Operating Temperature
- 40 C
On-chip Adc
12 bit, 8 Channel
On-chip Dac
10 bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
622-1005 - USB IN-CIRCUIT PROG ARM7 LPC2K
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-4966
935290522551

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPC1769FBD100,551
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
Table 320. CAN Interrupt and Capture Register (CAN1ICR - address 0x4004 400C, CAN2ICR - address 0x4004 800C)
UM10360
User manual
Bit
20:16 ERRBIT
21
23:22 ERRC1:0
Symbol
4:0
ERRDIR
[3]
bit description
Value
00011
00010
00110
00100
00101
00111
01111
01110
01100
01101
01001
01011
01010
01000
11000
11001
11011
11010
10010
10001
10110
10011
10111
11100
0
1
00
01
10
11
Function
Error Code Capture: when the CAN controller detects a bus error, the location of
the error within the frame is captured in this field. The value reflects an internal
state variable, and as a result is not very linear:
Start of Frame
ID28 ... ID21
ID20 ... ID18
SRTR Bit
IDE bit
ID17 ... 13
ID12 ... ID5
ID4 ... ID0
RTR Bit
Reserved Bit 1
Reserved Bit 0
Data Length Code
Data Field
CRC Sequence
CRC Delimiter
Acknowledge Slot
Acknowledge Delimiter
End of Frame
Intermission
Active Error Flag
Passive Error Flag
Tolerate Dominant Bits
Error Delimiter
Overload flag
When the CAN controller detects a bus error, the direction of the current bit is
captured in this bit.
Error occurred during transmitting.
Error occurred during receiving.
When the CAN controller detects a bus error, the type of error is captured in this
field:
Bit error
Form error
Stuff error
Other error
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 19 August 2010
Chapter 16: LPC17xx CAN1/2
UM10360
© NXP B.V. 2010. All rights reserved.
Reset
Value
0
0
0
359 of 840