EZ80F91MCU ZILOG [Zilog, Inc.], EZ80F91MCU Datasheet - Page 319
EZ80F91MCU
Manufacturer Part Number
EZ80F91MCU
Description
eZ80Acclaim-TM Flash Microcontrollers
Manufacturer
ZILOG [Zilog, Inc.]
Datasheet
1.EZ80F91MCU.pdf
(396 pages)
- Current page: 319 of 396
- Download datasheet (5Mb)
PS019209-0504
ZDI Write Data Registers
These three registers are used in the ZDI Write Only register address space to
store the data that is written when a Write instruction is sent to the ZDI Read/Write
Control register (ZDI_RW_CTL). The ZDI Read/Write Control register is located at
ZDI address
the ZDI Master is allowed to write the data to {ZDI_WR_U, ZDI_WR_H,
ZDI_WR_L} and the Write command in one data transfer operation. See Table
191.
Table 191. ZDI Write Data Registers
(ZDI_WR_U = 13h, ZDI_WR_H = 14h, and ZDI_WR_L = 15h
in the ZDI Register Write Only Address Space)
ZDI Read/Write Control Register
The ZDI Read/Write Control register is used in the ZDI Write Only Register
address to read data from, write data to, and manipulate the CPU’s registers or
memory locations. When this register is written, the eZ80F91 device immediately
performs the operation corresponding to the data value written as described in
Table 192. When a Read operation is executed via this register, the requested
data values are placed in the ZDI Read Data registers {ZDI_RD_U, ZDI_RD_H,
ZDI_RD_L}. When a Write operation is executed via this register, the Write data is
taken from the ZDI Write Data registers {ZDI_WR_U, ZDI_WR_H, ZDI_WR_L}.
See Table 192. Refer to the eZ80 CPU User Manual (UM0077) on
information regarding the CPU registers.
Bit
Reset
CPU Access
Note: X = Undefined; W = Write.
Bit
Position
[7:0]
ZDI_WR_L,
ZDI_WR_H,
or
ZDI_WR_L
16h
immediately following the ZDI Write Data registers. As a result,
Value Description
00h–
FFh
W
P R E L I M I N A R Y
X
7
These registers contain the data that is written during
execution of a Write operation defined by the
ZDI_RW_CTL register. The 24-bit data value is stored as
{ZDI_WR_U, ZDI_WR_H, ZDI_WR_L}. If less than 24 bits
of data are required to complete the required operation,
the data is taken from the least-significant byte(s).
W
6
X
W
X
5
W
X
4
W
X
3
Product Specification
W
X
ZiLOG Debug Interface
2
eZ80F91 MCU
zilog.com
W
X
1
W
for
X
0
300
Related parts for EZ80F91MCU
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
KIT DEV EZ80 WEB SERVER
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC EZ80 MPU 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC EZ80 MPU 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC EZ80 MPU 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC EZ80 MPU 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC EZ80 ACCLAIM 50MHZ 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC EZ80 ACCLAIM 50MHZ 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC WEBSERVER 20MHZ 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC WEBSERVER 50MHZ 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC WEBSERVER 8 BIT 50MHZ 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC WEBSERVER 50MHZ 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC WEBSERVER 50MHZ XTEMP 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC WEBSERVER 20MHZ 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC ACCLAIM MCU 64KB 100LQFP
Manufacturer:
Zilog
Datasheet:
Part Number:
Description:
IC ACCLAIM MCU 64KB 100LQFP
Manufacturer:
Zilog
Datasheet: