Figure 10.90 shows an example of dead time compensation setting procedure by using three
counters in channel 5.
Example of Dead Time Compensation Setting Procedure
TCNT_5 input capture occurs
Complementary PWM mode
Start count operation in
External pulse width
Figure 10.90 Example of Dead Time Compensation Setting Procedure
Interrupt processing
channels 3 to 5
measurement
[1]
[2]
[3]
[4] *
[5]
[1] Place channels 3 and 4 in complementary PWM mode. For
[2] Specify the external pulse width measurement function for
[3] Set bits CST3 and CST4 in TSTR and bits CST5U, CST5V,
[4] When the capture condition specified in TIOR is satisfied,
[5] For U-phase dead time compensation, when an interrupt is
Notes: The PFC settings must be completed in advance.
details, refer to section 10.4.8, Complementary PWM Mode.
the target TIOR in channel 5. For details, refer to section
10.4.11, External Pulse Width Measurement.
and CST5W in TSTR2 to 1 to start count operation.
the TCNT_5 value is captured in TGR_5.
generated at the crest (TGIA_3) or trough (TCIV_4) in
complementary PWM mode, read the TGRU_5 value,
calculate the difference in time in TGRB_3, and write the
corrected value to TGRD_3 in the interrupt processing.
For the V phase and W phase, read the TGRV_5 and
TGRW_5 values and write the corrected values to TGRC_4
and TGRD_4, respectively, in the same way as for U-phase
compensation.
The TCNT_5 value should be cleared through the
TCNTCMPCLR setting or by software.
* As an interrupt flag is set under the capture condition
specified in TIOR, do not enable interrupt requests in
TIER_5.
Section 10 Multi-Function Timer Pulse Unit 2 (MTU2)
Rev. 2.00 Dec. 09, 2005 Page 585 of 1152