HD64F7047FW40V Renesas Electronics America, HD64F7047FW40V Datasheet - Page 240

MCU 5V 256K I-TEMP,PB-FREE 100-Q

HD64F7047FW40V

Manufacturer Part Number
HD64F7047FW40V
Description
MCU 5V 256K I-TEMP,PB-FREE 100-Q
Manufacturer
Renesas Electronics America
Series
SuperH® SH7047r
Datasheet

Specifications of HD64F7047FW40V

Core Processor
SH-2
Core Size
32-Bit
Speed
40MHz
Connectivity
CAN, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
53
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 16x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F7047FW40V
0
Input Capture Function: The TCNT value can be transferred to TGR on detection of the TIOC
pin input edge.
Rising edge, falling edge, or both edges can be selected as the detected edge. For channels 0 and 1,
it is also possible to specify another channel's counter input clock or compare match signal as the
input capture source.
Note: When another channel's counter input clock is used as the input capture input for channels
1. Example of Input Capture Operation Setting Procedure
2. Example of Input Capture Operation
Rev. 2.00, 09/04, page 198 of 720
Figure 10.9 shows an example of the input capture operation setting procedure.
Figure 10.10 shows an example of input capture operation.
In this example both rising and falling edges have been selected as the TIOCA pin input
capture input edge, the falling edge has been selected as the TIOCB pin input capture input
edge, and counter clearing by TGRB input capture has been designated for TCNT.
0 and 1, φ/1 should not be selected as the counter input clock used for input capture input.
Input capture will not be generated if φ/1 is selected.
Figure 10.9 Example of Input Capture Operation Setting Procedure
<Input capture operation>
Select input capture input
Input selection
Start count
[1]
[2]
[1] Designate TGR as an input capture
[2] Set the CST bit in TSTR to 1 to start
register by means of TIOR, and select
rising edge, falling edge, or both edges
as the input capture source and input
signal edge.
the count operation.