hi-6131pqtf QuickLogic Corp, hi-6131pqtf Datasheet - Page 51

no-image

hi-6131pqtf

Manufacturer Part Number
hi-6131pqtf
Description
Mil-std-1553 / Mil-std-1760 3.3v Bc / Mt / Rt Multi-terminal Device
Manufacturer
QuickLogic Corp
Datasheet
Bit 3-0
Code
0000
0001
Negation Bit 4 = 0
compared values
Condition Code
or 0 based on
EQ / GP1 = 0
EQ / GP1 = 1
EQ / GP1 = 0
EQ / GP1 = 0
LT / GP0 = 1
LT / GP0 = 0
LT / GP0 = 0
LT / GP0 = 1
EQ / GP1
LT / GP0
Table 5. Bus Controller Condition Code Table
Negation Bit 4 = 0
GT-EQ / GP0 = 0
GT-EQ / GP0 = 1
GT-EQ / GP0 = 1
compared values
Condition Code
0 or 1 based on
GT-EQ / GP0 =
GT-EQ / GP0
NE / GP1 = 1
NE / GP1 = 0
NE / GP1 = 1
NE / GP1 = 1
NE / GP1
HOLT INTEGRATED CIRCUITS
HI-6130, HI-6131
Function
Less Than or GP0 Flag.
This flag may be toggled, set or cleared when the BC logic
executes a FLG (General Purpose Flags Bits) op code, or
when the host writes the BC General Purpose Flag Register
0x0037.
This flag is also set or cleared based on the evaluation of a
CMT (Compare Message Timer) or CFT (Compare Frame
Timer) instruction op code:
If CMT parameter < BC Time to Next Message Reg
If CFT parameter < BC Frame Time Remaining Reg
If CMT parameter = BC Time to Next Message Reg
If CFT parameter = BC Frame Time Remaining Reg
If CMT parameter > BC Time to Next Message Reg
If CFT parameter > BC Frame Time Remaining Reg
If CMT parameter ≠ BC Time to Next Message Reg
If CFT parameter ≠ BC Frame Time Remaining Reg
Equal To or GP1 Flag.
This flag may be toggled, set or cleared when the BC logic
executes a FLG (General Purpose Flags Bits) op code, or
when the host writes the BC General Purpose Flag Register
0x0037.
This flag is also set or cleared based on the evaluation of a
CMT (Compare Message Timer) or CFT (Compare Frame
Timer) instruction op code:
If CMT parameter < BC Time to Next Message Reg
If CFT parameter < BC Frame Time Remaining Reg
If CMT parameter = BC Time to Next Message Reg
If CFT parameter = BC Frame Time Remaining Reg
If CMT parameter > BC Time to Next Message Reg
If CFT parameter > BC Frame Time Remaining Reg
If CMT parameter ≠ BC Time to Next Message Reg
If CFT parameter ≠ BC Frame Time Remaining Reg
51