hi-6131pqtf QuickLogic Corp, hi-6131pqtf Datasheet - Page 119

no-image

hi-6131pqtf

Manufacturer Part Number
hi-6131pqtf
Description
Mil-std-1553 / Mil-std-1760 3.3v Bc / Mt / Rt Multi-terminal Device
Manufacturer
QuickLogic Corp
Datasheet
Bit No.
8
7
6
5
4
3
2
Mnemonic
GDB
Reserved
SFS
LE
SE
WE
RRGSA
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
HOLT INTEGRATED CIRCUITS
Function
Good Data Block Transfer.
only if Extended Status is enabled
Bit 8 is set to logic 1 following completion of a valid, error-free message.
This bit is reset to logic 0 following completion of a message in which
error occurred. If an RT responds to a transmit command with Busy
status without transmitting the commanded data word(s), this message
does not reset the GDB bit.
Bit 7 is not used in IMT mode, always reads logic 0.
Status Flag Set
only if Extended Status is enabled
Bit 6 is logic 1 when a status bit was set in an RT Status Word response.
Length (Word Count) Error
Bit 5 indicates that the number of data words transmitted by the BC or
RT differs from the Word Count specified in the Command Word. An RT
Status Word with the Busy bit set will not cause Word Count Error. A
transmit command with Response Timeout will not cause Word Count
Error.
Sync Type Error
Bit 4 is logic 1 to indicate that a BC transmitted data sync with a
Command Word, or a command / status sync occurred with Data Word,
or an RT responded with data sync in its Status Word and/or command/
status sync in a Data Word.
Invalid Word Error (WE)
Bit 3 is logic 1 when invalid word error occurred. This includes
Manchester decoding errors in the sync pattern or word bits, or the
wrong number of bits in the word, or parity error.
RT-to-RT Gap/Sync/Address Error (RRGSA)
only if Extended Status is enabled
Bit 2 is logic 1 if one or more of these RT-RT message conditions occur:
HI-6130, HI-6131
MT Gap Check is enabled (bit 12 equals 1 in register 0x0029) and
an RT Status Word is received having a response time less than
4µs, per MIL-STD-1553B (mid-parity to mid-sync). In other words,
the bus “dead time” was less than 2µs.
One of the RTs responds with an invalid Status Word, having a sync
error, a Manchester encoding error, bit count error and/or parity error
One of the RT Status Words contains an RT Address that differs
from the RT Address in the corresponding Command Word.
119