MOD5272-100IR NetBurner Inc, MOD5272-100IR Datasheet - Page 241

PROCESSOR MODULE FLASH MOD5272

MOD5272-100IR

Manufacturer Part Number
MOD5272-100IR
Description
PROCESSOR MODULE FLASH MOD5272
Manufacturer
NetBurner Inc
Type
Controllers & Processorsr

Specifications of MOD5272-100IR

Module/board Type
Processor Module
Ethernet Connection Type
10/100 Ethernet Port RJ-45
Operating Voltage
3.3 V
Product
Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
MOD5272
For Use With
528-1001 - KIT DEVELOP NETWORK FOR MOD5272
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
528-1008
MOTOROLA
11.5.7 MII Management Frame Register (MMFR)
The MMFR register, Figure 11-10, is used to communicate with the attached MII
compatible PHY device(s), providing read/write access to their MII registers. Performing
a write to the MMFR register causes a management frame to be sourced, unless the MSCR
register has been programmed to 0. In the case of writing to MMFR when MSCR = 0, if the
MSCR register is then written to a non-zero value, an MII frame is generated with the data
previously written to MMFR. This allows MMFR and MSCR to be programmed in either
order if MSCR is currently zero.
Table 11-13 describes the MMFR fields.
To perform a read or write operation on the MII management interface, the MMFR register
is written by the user. To generate a valid read or write management frame, the ST field must
be written with a 01 pattern, the OP field must be written with a 01 (management register
write frame) or 10 (management register read frame), and the TA field must be written with
a 10. If other patterns are written to these fields, a frame is generated but will not comply
with the IEEE 802.3 MII definition. OP field = 1x produces a read-frame operation, while
OP = 0x produces a write-frame operation.
Reset
Reset
31–30
29–28
27–23
22–18
17–16
15–0
Field
Field
Bits
Addr
R/W
R/W
31
15
Name
DATA
ST
OP
RA
ST
PA
TA
30
Figure 11-10. MII Management Frame Register (MMFR)
Start of frame delimiter. Must be programmed to 01 for a valid MII management frame
Operation code. This field must be programmed to 10 (read) or 01(write) to generate a valid
MII management frame. A value of 11 produces a read frame operation while a value of 00
produces a write frame operation, but these frames are not MII-compliant.
PHY address. Specifies one of up to 32 attached PHY devices
Register address. Specifies one of up to 32 registers within the specified PHY device
Turn around. Must be programmed to 10 to generate a valid MII management frame.
Management frame data. Field for data to be written to or read from PHY register
29
OP
28
Table 11-13. MMFR Field Descriptions
27
Chapter 11. Ethernet Module
PA
MBAR + 0x880
Read/Write
Read/Write
Undefined
Undefined
23
DATA
Description
22
RA
Programming Model
18
17
TA
11-17
16
0