mcf51ac256a Freescale Semiconductor, Inc, mcf51ac256a Datasheet - Page 284

no-image

mcf51ac256a

Manufacturer Part Number
mcf51ac256a
Description
Mcf51ac Flexis
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mcf51ac256aCFGE
Manufacturer:
FREESCALE
Quantity:
2 400
Part Number:
mcf51ac256aCFGE
Manufacturer:
FREESCALE
Quantity:
2 400
Part Number:
mcf51ac256aCFUE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf51ac256aCLKE
Manufacturer:
FREESCALE
Quantity:
1 500
Part Number:
mcf51ac256aCLKE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf51ac256aCPUE
Manufacturer:
MURATA
Quantity:
1 000
Inter-Integrated Circuit (IICV2)
12.4.1.3
Before successful slave addressing is achieved, the data transfer can proceed byte-by-byte in a direction
specified by the R/W bit sent by the calling master.
All transfers that come after an address cycle are referred to as data transfers, even if they carry sub-address
information for the slave device
Each data byte is 8 bits long. Data may be changed only while SCL is low and must be held stable while
SCL is high as shown in
transferred first. Each data byte is followed by a 9th (acknowledge) bit, which is signalled from the
receiving device. An acknowledge is signalled by pulling the SDA low at the ninth clock. In summary, one
complete data transfer needs nine clock pulses.
If the slave receiver does not acknowledge the master in the ninth bit time, the SDA line must be left high
by the slave. The master interprets the failed acknowledge as an unsuccessful data transfer.
If the master receiver does not acknowledge the slave transmitter after a data byte transmission, the slave
interprets this as an end of data transfer and releases the SDA line.
In either case, the data transfer is aborted and the master does one of two things:
12.4.1.4
The master can terminate the communication by generating a stop signal to free the bus. However, the
master may generate a start signal followed by a calling command without generating a stop signal first.
This is called repeated start. A stop signal is defined as a low-to-high transition of SDA while SCL at
logical 1 (see
The master can generate a stop even if the slave has generated an acknowledge at which point the slave
must release the bus.
12.4.1.5
As shown in
signal to terminate the communication. This is used by the master to communicate with another slave or
with the same slave in different mode (transmit/receive mode) without releasing the bus.
12.4.1.6
The IIC bus is a true multi-master bus that allows more than one master to be connected on it. If two or
more masters try to control the bus at the same time, a clock synchronization procedure determines the bus
clock, for which the low period is equal to the longest clock low period and the high is equal to the shortest
one among the masters. The relative priority of the contending masters is determined by a data arbitration
procedure, a bus master loses arbitration if it transmits logic 1 while another master transmits logic 0. The
losing masters immediately switch over to slave receive mode and stop driving SDA output. In this case,
12-12
Relinquishes the bus by generating a stop signal.
Commences a new calling by generating a repeated start signal.
Figure
Data Transfer
Stop Signal
Repeated Start Signal
Arbitration Procedure
Figure
MCF51AC256 ColdFire Integrated Microcontroller Reference Manual, Rev. 5
12-8, a repeated start signal is a start signal generated without first generating a stop
12-8).
Figure
12-8. There is one clock pulse on SCL for each data bit, the msb being
Freescale Semiconductor

Related parts for mcf51ac256a