16.1.5 Interrupt Status Registers (Y30 - Y3F) Bit Functions
Interrupt status register bit functions are shown in Tables 105 to 108.
15-9
Bit
8
7
6
5
4
3
2
1
0
TXUNDERI Transmit Elastic Buffer Empty Interrupt. If high it Indicates that a read by the
RXOVFLI
EOPDI
EOPRI
TEOPI
RXFFI
Name
TXFLI
GAI
FAI
#
not used.
Go Ahead Interrupt. Indicates a go-ahead pattern (01111111) was detected by the
HDLC receiver. This bit is reset after a read of Y33 or Y23.
End of Packet Data Interrupt.This bit is set when an end of packet (EOP) byte was
written into the RX FIFO by the HDLC receiver. This can be in the form of a flag, an abort
sequence or as an invalid packet. This bit is reset after a read of Y33 or Y23.
Transmit End of Packet Interrupt.This bit is set when the transmitter has finished
sending the closing flag of a packet or after a packet has been aborted. This bit is reset
after a read of Y33 or Y23.
End of Packet Receive Fifo Interrupt.This bit is set when the byte about to be read
from the RX FIFO is the last byte of the packet. It is also set if the Rx FIFO is read and
there is no data in it.This bit is reset after a read of Y33 or Y23.
Transmit FIFO Low Interrupt.This bit is set when the Tx FIFO is emptied below the 16
byte low threshold level.This bit is reset after a read of Y33 or Y23.
Frame Abort: Transmit Interrupt. This bit (FA) is set when a frame abort is received
during packet reception. It must be received after a minimum number of bits have been
received (26) otherwise it is ignored. This bit is reset after a read of Y33 or Y23.
transmitter was attempted on an empty Tx FIFO. This bit is reset after a read of Y33 or
Y23.
Receive FIFO is filled above Threshold Interrupt.This bit is set when the Rx FIFO
is filled above the 16 byte full threshold level. This bit is reset after a read of Y33 or
Y23.
Receive Fifo Overflow Interrupt This bit
overflowed (i/.e. an attempt to write to a 32 byte full RX FIFO). The HDLC will always
disable the receiver once the receive overflow has been detected. The receiver will be
re-enabled upon detection of the next flag, but will overflow again unless the RX FIFO
is read. This bit is reset after a read of Y33 or Y23.
Table 105 - HDLC Interrupt Status Register(Y33) (T1)
Functional Description
Indicates that the 32 byte RX FIFO
MT9072
133
.

Related parts for MT9072