User manual
11.11.6.2 State: 0x20
11.11.6.3 State: 0x28
11.11.6.4 State: 0x30
11.11.6.5 State: 0x38
11.11.7.1 State: 0x40
11.11.7 Master Receive states
Slave Address + Write has been transmitted, NOT ACK has been received. A STOP
condition will be transmitted.
Data has been transmitted, ACK has been received. If the transmitted data was the last
data byte then transmit a STOP condition, otherwise transmit the next data byte.
Data has been transmitted, NOT ACK received. A STOP condition will be transmitted.
Arbitration has been lost during Slave Address + Write or data. The bus has been
released and not addressed Slave mode is entered. A new START condition will be
transmitted when the bus is free again.
Previous state was State 08 or State 10. Slave Address + Read has been transmitted,
ACK has been received. Data will be received and ACK returned.
1. Write 0x14 to CONSET to set the STO and AA bits.
2. Write 0x08 to CONCLR to clear the SI flag.
3. Exit
1. Decrement the Master data counter, skip to step 5 if not the last data byte.
2. Write 0x14 to CONSET to set the STO and AA bits.
3. Write 0x08 to CONCLR to clear the SI flag.
4. Exit
5. Load DAT with next data byte from Master Transmit buffer.
6. Write 0x04 to CONSET to set the AA bit.
7. Write 0x08 to CONCLR to clear the SI flag.
8. Increment Master Transmit buffer pointer
9. Exit
1. Write 0x14 to CONSET to set the STO and AA bits.
2. Write 0x08 to CONCLR to clear the SI flag.
3. Exit
1. Write 0x24 to CONSET to set the STA and AA bits.
2. Write 0x08 to CONCLR to clear the SI flag.
3. Exit
1. Write 0x04 to CONSET to set the AA bit.
2. Write 0x08 to CONCLR to clear the SI flag.