MCF5272VF66 Freescale, MCF5272VF66 Datasheet - Page 138

MCF5272VF66

Manufacturer Part Number
MCF5272VF66
Description
Manufacturer
Freescale
Datasheet

Specifications of MCF5272VF66

Family Name
MCF5xxx
Device Core
ColdFire
Device Core Size
32b
Frequency (max)
66MHz
Instruction Set Architecture
RISC
Supply Voltage 1 (typ)
3.3V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
196
Package Type
MA-BGA
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCF5272VF66
Manufacturer:
HYNIX
Quantity:
19
Part Number:
MCF5272VF66
Manufacturer:
FREESCAL
Quantity:
885
Part Number:
MCF5272VF66
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MCF5272VF66
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MCF5272VF66J
Manufacturer:
Freescale
Quantity:
256
Part Number:
MCF5272VF66J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MCF5272VF66R2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MCF5272VF66R2J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Debug Support
5.5.3.1
All ColdFire Family BDM commands include a 16-bit operation word followed by an optional set of one
or more extension words, as shown in
Table 5-18
5.5.3.1.1
Some commands require extension words for addresses and/or immediate data. Addresses require two
extension words because only absolute long addressing is permitted. Longword accesses are forcibly
longword-aligned and word accesses are forcibly word-aligned. Immediate data can be 1 or 2 words long.
Byte and word data each requires a single extension word and longword data requires two extension words.
Operands and addresses are transferred most-significant word first. In the following descriptions of the
BDM command set, the optional set of extension words is defined as address, data, or operand data.
5-20
15–10
7–6
5–4
2–0
Bit
9
8
3
15
Operation Specifies the command. These values are listed in
Operand
Register
Name
R/W
Size
describes BDM fields.
A/D
00
0
ColdFire BDM Command Format
Extension Words as Required
Operation
Reserved
Direction of operand transfer.
0 Data is written to the CPU or to memory from the development system.
1 The transfer is from the CPU to the development system.
Operand data size for sized operations. Addresses are expressed as 32-bit absolute values. Note that a
command performing a byte-sized memory read leaves the upper 8 bits of the response data undefined.
Referenced data is returned in the lower 8 bits of the response.
00 Byte8 bits
01 Word16 bits
10 Longword32 bits
11 Reserved—
Reserved
Address/data. Determines whether the register field specifies a data or address register.
0 Indicates a data register.
1 Indicates an address register.
Contains the register number in commands that operate on processor registers.
Operand SizeBit Values
MCF5272 ColdFire
Figure 5-15. BDM Command Format
Table 5-18. BDM Field Descriptions
10
®
Figure
Integrated Microprocessor User’s Manual, Rev. 3
0
9
Extension Word(s)
5-15.
R/W
8
7
Op Size
Description
6
Table
5-17.
0
5
0
4
A/D
3
Freescale Semiconductor
2
Register
0

Related parts for MCF5272VF66