cx28365 Mindspeed Technologies, cx28365 Datasheet - Page 172

no-image

cx28365

Manufacturer Part Number
cx28365
Description
X12, X6, X4 T3/e3 Framer And Atm Cell Transmission Convergence Sublayer Processor
Manufacturer
Mindspeed Technologies
Datasheet
Registers
3.4.6
0x40—SR00 (DS3/E3 Maintenance Status Register)
ReFrm
LOSAlm
IdleDet
YelDet
AISDet
OOFAlm
3-62
ReFrm
7
Reframe in Progress—Set while the framing circuit searches for a valid framing pattern in
either DS3 or E3 modes.
Loss-of-Signal Alarm—Indicates that the received signal has been lost prior to B3ZS/HDB3
decoding. This signal is set as soon as the receiver detects the loss-of-signal condition and
clears when the receiver detects a legal signal.
Idle Code Detect—Set if an idle pattern is found. This bit is low in E3 modes, since there is no
defined E3 idle signal.
Yellow Alarm Detect—Set when a RAI/RDI event is detected in the receiver.
Alarm Indication Signal Detect—Set if the receiver detects an AIS event.
Out of Frame Alarm—Set when an OOF condition is detected by the receiver. This condition
initiates a reframe.
Framer Channel Status Registers
6
The DS3/E3 Maintenance Status register contains the major DS3/E3 maintenance
indicators.
Value after reset: 81
Direction: Read only
Value after enable:
NOTE:
Preliminary Information/Mindspeed Proprietary and Confidential
5
Mindspeed Technologies™
RefrmStp—Bit 6 in CR08, Feature 5 Control register.
LOSAlm
4
If RefrmStp bit is clear—81
If RefrmStp bit is set—01
IdleDet
3
YelDet
2
AISDet
1
CX28365/6/4 Data Sheet
OOFAlm
0
500028C