no-image

UPD70F3786GJ-GAE-AX

Manufacturer Part Number
UPD70F3786GJ-GAE-AX
Description
MCU 32BIT V850ES/JX3-E 144-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Er
Datasheet

Specifications of UPD70F3786GJ-GAE-AX

Core Processor
RISC
Core Size
32-Bit
Speed
50MHz
Connectivity
CAN, CSI, EBI/EMI, Ethernet, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
100
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
124K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3786GJ-GAE-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
UPD70F3786GJ-GAE-AX
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
1452
31
30
29
28
27
26
25
24
23
22
21
20
19
(10) RXSTMONI: Reception status monitor register
Bit
Access
Address
Default value 0000 0000H. This register is cleared to its default value by all types of resets.
Notes 1. This bit is not set to 1 if a CRC error or RXER has occurred.
RLENE
VLAN
USOP
RPCF
RCFR
DBNB
RBRO
RMUL
RXOK
RLOR
RLER
RCRCE
RXER
RBYT15
RLENE
RBYT7
RXOK
2. This bit is not set to 1 if a CRC error has occurred.
3. This bit is not set to 1 if the MACC1.FLCHT bit is set to 0.
4. RLOR is set to 1 and RLER is not set to 1 if the length field exceeds 1,500.
31
23
15
Name
R
R
R
R
7
This register is read-only, in 32-bit units.
002E 0240H
RBYT14
RBYT6
RLOR
VLAN
Receive packet length error
This bit indicates that the received packet is less than 64 bytes or greater than 1,518 bytes (less
than 64 bytes or greater than 1,522 bytes in the case of VLAN).
VLAN packet
This bit indicates that a packet whose TPID field matches VLTP has been received
An undefined opcode control packet was received
A pause control packet was received
A control packet was received
A packet containing dribble nibble
A broadcast packet was received.
A multicast packet was received.
End of reception
A packet with a length field exceeding 1,500 bytes
The length field does not match the data field length
A CRC error has occurred.
RXER detection
30
22
14
R
R
R
R
6
RBYT13
RBYT5
USOP
RLER
CHAPTER 23 ETHERNET CONTROLLER
29
21
13
R
R
R
R
5
Note 1
User’s Manual U19601EJ2V0UD
RBYT12
RCRCE
RBYT4
RPCF
28
20
12
R
R
R
R
4
Note 2
Note 2
RBYT11
RBYT3
RCFR
RXER
27
19
11
R
R
R
R
3
Description
Note 2
Note 3
RBYT10
RBYT2
Notes 3, 4
DBNB
CEPS
.
was received.
26
18
10
R
R
R
R
2
.
RBYT9
RBYT1
RBRO
REPS
25
17
R
R
R
R
9
1
RBYT8
RBYT0
RMUL
PAIG
24
16
R
R
R
R
8
0
Note 1
.
(1/2)