BMSKTOPASA900(DCE) Toshiba, BMSKTOPASA900(DCE) Datasheet - Page 604

KIT STARTER TMPA900 USB JTAG

BMSKTOPASA900(DCE)

Manufacturer Part Number
BMSKTOPASA900(DCE)
Description
KIT STARTER TMPA900 USB JTAG
Manufacturer
Toshiba
Series
TOPASr
Type
MCUr
Datasheets

Specifications of BMSKTOPASA900(DCE)

Contents
Evaluation Board, Cable(s), Software and Documentation
For Use With/related Products
TMPA900CMXBG
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
bmRequestType
0y00000000
0y00000001
0y00000010
• Common to all states:
• Default state:
• Address state:
• Configured state:
Note: When using a vendor-specific Test Selector other than standard ones, the appropriate operation should be
Note 1: Endpoint 0 is to be stalled based on the interpretation of the USB specifications that "No Feature Selector
Note 2: USB 2.0 specifications include such description that "Performing the Halt function for Endpoint 0 is neither
(c) Set Feature request
made.
High-Speed, write the value of Test Selector (upper byte of wIndex) to the bits7-0(t_sel)
of USB-testmode register within 3 ms after the STATUS-Stage has ended.
specified for the Test Selector value, issue the EP-Stall command to EP0.
for the above-mentioned TEST_MODE.
SET_FEATURE
exists for Interface" here. For more information, see the USB specifications.
necessary nor recommended." Accordingly, it can be interpreted that it is not necessary to set UDC2 to the
Stall state in this case.
To this request, particular functions are set or enabled.
When Recipient = Device and wValue = 2 are specified in a device supporting
If, however, an invalid value (other than test_j, test_k, se0_nak, and test_packet) is
Nothing is specified for the operation of devices by the USB 2.0 specifications except
Recipient = Device
Recipient = Interface
Recipient = Endpoint
Recipient = Device
Recipient = Interface
Recipient = Endpoint
bRequest
• If Feature Selector (wValue) which cannot be set (enabled) or does not exist is
• If the Endpoint/Interface specified by the lower byte of wIndex does not exist,
specified, issue the EP-Stall command to EP0.
issue the EP-Stall command to EP0.
Feature Selector
wValue
TENTATIVE
TMPA900CM- 603
:
:
:
:
:
:
If wValue = 1, enable the
DEVICE_REMOTE_WAKEUP function at the user's
end. No register access to UDC2 is required.
Issue the EP-Stall command to EP0.
If the lower byte of wIndex ≠ 0 (EPx), issue the
EP-Stall command to EP0.
If wValue = 0 and the lower byte of wIndex = 0 (EP0),
make Endpoint 0 halt. (Note 2)
If wValue = 1, enable the
DEVICE_REMOTE_WAKEUP function at the
user's end. No register access to UDC2 is required.
Issue the EP-Stall command to EP0. (Note 1)
If wValue = 0 and the lower byte of wIndex ≠ 0
(EPx), issue the EP-Stall command to the relevant
endpoint. If wValue = 0 and the lower byte of wIndex
= 0 (EP0), make Endpoint 0 halt. (Note 2)
Endpoint
Interface
Zero
wIndex
Test Selector
wLength
Zero
TMPA900CM
2009-10-14
Data
None

Related parts for BMSKTOPASA900(DCE)