BMSKTOPASA900(DCE) Toshiba, BMSKTOPASA900(DCE) Datasheet - Page 576

KIT STARTER TMPA900 USB JTAG

BMSKTOPASA900(DCE)

Manufacturer Part Number
BMSKTOPASA900(DCE)
Description
KIT STARTER TMPA900 USB JTAG
Manufacturer
Toshiba
Series
TOPASr
Type
MCUr
Datasheets

Specifications of BMSKTOPASA900(DCE)

Contents
Evaluation Board, Cable(s), Software and Documentation
For Use With/related Products
TMPA900CMXBG
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
k. < i_ep0>
l.
m. <i_rx_data0>
n. <i_status>
o. <i_status_nak>
p. <i_status_nak>
< i_sof>
This will be set to 1 when the SOF-token is received or after 1 frame-time was counted in
the create_sof mode.
This will be set to 1 when Zero-Length data is received. (EPs to which you wish to output
the flag can be selected using INT_EP_MASK register). Writing 1 to this bit will make
each bit of INT_RX_DATA0 register cleared to 0. This will not be set to 1 when
Zero-Length data is received in the STATUS-Stage of Control-RD transfers.
This will be set to 1 when the STATUS-Stage has successfully finished in Control
transfers at EP0. (This will be set to 1 when Zero-Length data is received in the
STATUS-Stage and successfully finished in Control-RD transfers, and when Zero-Length
data is transmitted in the STATUS-Stage and successfully finished in Control-WR
transfers.)
This will be set to 1 when the packet of STATUS-Stage is received in the Control-RD
transfers at EP0. When this bit was set which means the DATA-Stage has finished, set
the “Setup-Fin” command by the Command register to make the stage of UDC2 proceed to
the STATUS-Stage. When receiving the data having the size of an integral multiple of
MaxPacketSize (64 bytes: High-Speed) in the DATA-Stage of Control-WR transfers,
Zero-Length data may be received to indicate the end of the DATA-Stage. After that, as
the end of the DATA-Stage can be recognized by this i_status_nak when receiving the
In-token in the STATUS-Stage, make UDC2 proceed to the STATUS-Stage.
This will be set to 1 when the Setup-Token was received in Control transfers at EP0.
This will be set to 1 when the transfer to EP0 has successfully finished.
TENTATIVE
TMPA900CM- 575
TMPA900CM
2009-10-14