BMSKTOPASA900(DCE) Toshiba, BMSKTOPASA900(DCE) Datasheet - Page 539

KIT STARTER TMPA900 USB JTAG

BMSKTOPASA900(DCE)

Manufacturer Part Number
BMSKTOPASA900(DCE)
Description
KIT STARTER TMPA900 USB JTAG
Manufacturer
Toshiba
Series
TOPASr
Type
MCUr
Datasheets

Specifications of BMSKTOPASA900(DCE)

Contents
Evaluation Board, Cable(s), Software and Documentation
For Use With/related Products
TMPA900CMXBG
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
(3) Setting the maximum packet size in Master Read transfers
function of UDC2AB will be an odd number, there will be following restrictions to
which you should pay attention:
Note:
If the maximum packet size of the endpoint to be connected with the Master Read
(Example) A setting satisfying the above conditions:
• Even if the maximum packet size of the endpoint should be handled as an odd
• Set the eopb_enable bit of UDC2 Setting register to 1 (Master Read EOP
• Make the transfer size to be specified for one Master Read transfer (Master
• Set the maximum packet size of the endpoint (value to pass to the USB host) to
• Make the setting of the max_pkt bit of UDC2 EPx_MaxPacketSize register to
• Keep the transfer size to be specified for one Master Read transfer to 63 bytes
Refer to the "section 3.16.4.2 “Appendix B
MaxPacketSize" for more information on this setting.
number, the setting of the max_pkt bit of UDC2 EPx_MaxPacketSize register
should be an even number.
enable).
Read End Address - Master Read Start Address + 1) not exceed the maximum
packet size of an odd number.
be 63 bytes.
be 64 bytes.
or less.
TENTATIVE
TMPA900CM- 538
About Setting an Odd Number of Bytes as
TMPA900CM
2009-10-14

Related parts for BMSKTOPASA900(DCE)