sc9s12hy64j0vllr Freescale Semiconductor, Inc, sc9s12hy64j0vllr Datasheet - Page 428

no-image

sc9s12hy64j0vllr

Manufacturer Part Number
sc9s12hy64j0vllr
Description
S12 Microcontrollers Mcu 16-bit Hcs12 Cisc 32kb Flash 5v Tray
Manufacturer
Freescale Semiconductor, Inc
Datasheet
Serial Communication Interface (S12SCIV5)
428
Field
ILT
PE
PT
2
1
0
LOOPS
Idle Line Type Bit — ILT determines when the receiver starts counting logic 1s as idle character bits. The
counting begins either after the start bit or after the stop bit. If the count begins after the start bit, then a string of
logic 1s preceding the stop bit may cause false recognition of an idle character. Beginning the count after the
stop bit avoids false idle character recognition, but requires properly synchronized transmissions.
0 Idle character bit count begins after start bit
1 Idle character bit count begins after stop bit
Parity Enable Bit — PE enables the parity function. When enabled, the parity function inserts a parity bit in the
most significant bit position.
0 Parity function disabled
1 Parity function enabled
Parity Type Bit — PT determines whether the SCI generates and checks for even parity or odd parity. With even
parity, an even number of 1s clears the parity bit and an odd number of 1s sets the parity bit. With odd parity, an
odd number of 1s clears the parity bit and an even number of 1s sets the parity bit.
0 Even parity
1 Odd parity
0
1
1
RSRC
x
0
1
Table 12-4. SCICR1 Field Descriptions (continued)
MC9S12HY/HA-Family Reference Manual, Rev. 1.04
Normal operation
Loop mode with transmitter output internally connected to receiver input
Single-wire mode with TXD pin connected to receiver input
Table 12-5. Loop Functions
Description
Function
Freescale Semiconductor