sc9s12hy64j0vllr Freescale Semiconductor, Inc, sc9s12hy64j0vllr Datasheet - Page 360

no-image

sc9s12hy64j0vllr

Manufacturer Part Number
sc9s12hy64j0vllr
Description
S12 Microcontrollers Mcu 16-bit Hcs12 Cisc 32kb Flash 5v Tray
Manufacturer
Freescale Semiconductor, Inc
Datasheet
Freescale’s Scalable Controller Area Network (S12MSCANV3)
9.5
9.5.1
The procedure to initially start up the MSCAN module out of reset is as follows:
If the configuration of registers which are only writable in initialization mode shall be changed:
9.5.2
The bus-off recovery is user configurable. The bus-off state can either be left automatically or on user
request.
For reasons of backwards compatibility, the MSCAN defaults to automatic recovery after reset. In this
case, the MSCAN will become error active again after counting 128 occurrences of 11 consecutive
recessive bits on the CAN bus (see the Bosch CAN specification for details).
If the MSCAN is configured for user request (BORM set in MSCAN Control Register 1 (CANCTL1)), the
recovery from bus-off starts after both independent events have become true:
These two events may occur in any order.
360
1. Assert CANE
2. Write to the configuration registers in initialization mode
3. Clear INITRQ to leave initialization mode
1. Bring the module into sleep mode by setting SLPRQ and awaiting SLPAK to assert after the CAN
2. Enter initialization mode: assert INITRQ and await INITAK
3. Write to the configuration registers in initialization mode
4. Clear INITRQ to leave initialization mode and continue
bus becomes idle.
128 occurrences of 11 consecutive recessive bits on the CAN bus have been monitored
BOHOLD in MSCAN Miscellaneous Register (CANMISC) has been cleared by the user
Initialization/Application Information
MSCAN initialization
Bus-Off Recovery
MC9S12HY/HA-Family Reference Manual, Rev. 1.04
Freescale Semiconductor

Related parts for sc9s12hy64j0vllr