sc9s12hy64j0vllr Freescale Semiconductor, Inc, sc9s12hy64j0vllr Datasheet - Page 238

no-image

sc9s12hy64j0vllr

Manufacturer Part Number
sc9s12hy64j0vllr
Description
S12 Microcontrollers Mcu 16-bit Hcs12 Cisc 32kb Flash 5v Tray
Manufacturer
Freescale Semiconductor, Inc
Datasheet
S12 Clock, Reset and Power Management Unit (S12CPMU) Block Description
Write: Refer to each bit for individual write conditions
238
LOCKIF
UPOSC
OSCIF
PORF
LOCK
Field
LVRF
RTIF
ILAF
7
6
5
4
3
2
1
0
Real Time Interrupt Flag — RTIF is set to 1 at the end of the RTI period. This flag can only be cleared by writing
a 1. Writing a 0 has no effect. If enabled (RTIE=1), RTIF causes an interrupt request.
0 RTI time-out has not yet occurred.
1 RTI time-out has occurred.
Power on Reset Flag — PORF is set to 1 when a power on reset occurs. This flag can only be cleared by writing
a 1. Writing a 0 has no effect.
0 Power on reset has not occurred.
1 Power on reset has occurred.
Low Voltage Reset Flag — LVRF is set to 1 when a low voltage reset occurs. This flag can only be cleared by
writing a 1. Writing a 0 has no effect.
0 Low voltage reset has not occurred.
1 Low voltage reset has occurred.
PLL Lock Interrupt Flag — LOCKIF is set to 1 when LOCK status bit changes. This flag can only be cleared by
writing a 1. Writing a 0 has no effect.If enabled (LOCKIE=1), LOCKIF causes an interrupt request.
0 No change in LOCK bit.
1 LOCK bit has changed.
Lock Status Bit — LOCK reflects the current state of PLL lock condition. Writes have no effect. While PLL is
unlocked (LOCK=0) f
stabilization time tlock.
0 VCOCLK is not within the desired tolerance of the target frequency.
1 VCOCLK is within the desired tolerance of the target frequency.
Illegal Address Reset Flag — ILAF is set to 1 when an illegal address reset occurs. Refer to MMC chapter for
details. This flag can only be cleared by writing a 1. Writing a 0 has no effect.
0 Illegal address reset has not occurred.
1 Illegal address reset has occurred.
Oscillator Interrupt Flag — OSCIF is set to 1 when UPOSC status bit changes. This flag can only be cleared
by writing a 1. Writing a 0 has no effect.If enabled (OSCIE=1), OSCIF causes an interrupt request.
0 No change in UPOSC bit.
1 UPOSC bit has changed.
Oscillator Status Bit — UPOSC reflects the status of the oscillator. Writes have no effect. While UPOSC=0 the
OSCCLK going to the MSCAN module is off. Entering Full Stop Mode UPOSC is cleared.
0 The oscillator is off or oscillation is not qualified by the PLL.
1 The oscillator is qualified by the PLL.
qualify the external oscillator clock. Because of this, the PLL is always active
and a valid PLL configuration is required for the system to work properly.
Furthermore, the adaptive spike filter is used to determine the status of the
external oscillator (reflected in the UPOSC bit). Since this function also relies on
the VCO clock, loosing PLL lock status (LOCK=0, except for entering Pseudo
Stop Mode) means loosing the oscillator status information as well (UPOSC=0).
f
f
The adaptive spike filter uses the VCO clock as a reference to continuously
PLL
PLL
= f
= f
VCO
VCO
/4.
/(POSTDIV+1).
MC9S12HY/HA-Family Reference Manual, Rev. 1.04
PLL
Table 7-3. CPMUFLG Field Descriptions
is f
VCO
/ 4 to protect the system from high core clock frequencies during the PLL
NOTE
Description
Freescale Semiconductor

Related parts for sc9s12hy64j0vllr