HD64F2612FA20 Renesas Electronics America, HD64F2612FA20 Datasheet - Page 389

IC H8S MCU FLASH 128K 80QFP

HD64F2612FA20

Manufacturer Part Number
HD64F2612FA20
Description
IC H8S MCU FLASH 128K 80QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2612FA20

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
43
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
80-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2612FA20
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD64F2612FA20J
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
No
No
No
Figure 14.13 Sample Multiprocessor Serial Reception Flowchart (1)
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Read RDRF flag in SSR
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Read MPIE bit in SCR
All data received?
FER ∨ ORER = 1
FER ∨ ORER = 1
This station's ID?
Start reception
Initialization
RDRF = 1
RDRF = 1
<End>
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
Error processing
[3]
[1]
[2]
(Continued on
next page)
Section 14 Serial Communication Interface (SCI)
[4]
[5]
[1] SCI initialization:
[2] ID reception cycle:
[3] SCI status check, ID reception and
[4] SCI status check and data reception:
[5] Receive error processing and break
Rev. 7.00 Sep. 11, 2009 Page 353 of 566
The RxD pin is automatically designated
as the receive data input pin.
Set the MPIE bit in SCR to 1.
comparison:
Read SSR and check that the RDRF
flag is set to 1, then read the receive
data in RDR and compare it with this
station's ID.
If the data is not this station's ID, set the
MPIE bit to 1 again, and clear the RDRF
flag to 0.
If the data is this station's ID, clear the
RDRF flag to 0.
Read SSR and check that the RDRF
flag is set to 1, then read the data in
RDR.
detection:
If a receive error occurs, read the ORER
and FER flags in SSR to identify the
error. After performing the appropriate
error processing, ensure that the ORER
and FER flags are all cleared to 0.
Reception cannot be resumed if either
of these flags is set to 1.
In the case of a framing error, a break
can be detected by reading the RxD pin
value.
REJ09B0211-0700

Related parts for HD64F2612FA20