EP4CGX150CF23I7N Altera, EP4CGX150CF23I7N Datasheet - Page 235

no-image

EP4CGX150CF23I7N

Manufacturer Part Number
EP4CGX150CF23I7N
Description
IC CYCLONE IV FPGA 150K 484FBGA
Manufacturer
Altera
Series
CYCLONE® IV GXr

Specifications of EP4CGX150CF23I7N

Number Of Logic Elements/cells
149760
Number Of Labs/clbs
9360
Total Ram Bits
6480000
Number Of I /o
270
Voltage - Supply
1.16 V ~ 1.24 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
484-FBGA
Family Name
Cyclone IV
Number Of Logic Blocks/elements
149760
# I/os (max)
270
Operating Supply Voltage (typ)
1.2V
Logic Cells
149760
Ram Bits
6635520
Operating Supply Voltage (min)
1.16V
Operating Supply Voltage (max)
1.24V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
484
Package Type
FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CGX150CF23I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CGX150CF23I7N
Manufacturer:
ALTERA
0
Part Number:
EP4CGX150CF23I7N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4CGX150CF23I7N
0
Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices
Remote System Upgrade
Enabling Remote Update
© December 2010 Altera Corporation
Figure 8–31
Cyclone IV devices.
Figure 8–31. Remote System Upgrade Block Diagrams for AS and AP Configuration Schemes
The MSEL pin setting in the remote system upgrade mode is the same as the standard
configuration mode. Standard configuration mode refers to normal Cyclone IV device
configuration mode with no support for remote system upgrades (the remote system
upgrade circuitry is disabled). When using remote system upgrade in Cyclone IV
devices, you must enable the remote update mode option setting in the Quartus II
software.
You can enable or disable remote update for Cyclone IV devices in the Quartus II
software before design compilation (in the Compiler Settings menu). To enable remote
update in the compiler settings of the project, perform the following steps:
1. On the Assignments menu, click Device. The Settings dialog box appears.
2. Click Device and Pin Options. The Device and Pin Options dialog box appears.
3. Click the Configuration tab.
4. From the Configuration Mode list, select Remote.
5. Click OK.
6. In the Settings dialog box, click OK.
Configuration Image Types
When using remote system upgrade, Cyclone IV device configuration bitstreams are
classified as factory configuration images or application configuration images. An
image, also referred to as a configuration, is a design loaded into the device that
performs certain user-defined functions. Each device in your system requires one
factory image or with addition of one or more application images. The factory image
is a user-defined fall-back or safe configuration and is responsible for administering
remote updates with the dedicated circuitry. Application images implement
user-defined functionality in the target Cyclone IV device. You can include the default
application image functionality in the factory image.
shows the block diagrams to implement remote system upgrade in
Nios Processor or User Logic
Serial Configuration Device
Serial Configuration Device
Cyclone IV Device
Nios Processor or User Logic
Supported Parallel Flash
Parallel Flash Memory
Cyclone IV E Device
Cyclone IV Device Handbook, Volume 1
8–69

Related parts for EP4CGX150CF23I7N