Specifications of HD64F2623FA20J

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
53
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2623FA20J
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F2623FA20J
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F2623FA20J
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD64F2623FA20JV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Bit 5—A/D Start (ADST): Selects starting or stopping on A/D conversion. Holds a value of 1
during A/D conversion.
The ADST bit can be set to 1 by software, a timer conversion start trigger, or the A/D external
trigger input pin (ADTRG).
Bit 4—Scan Mode (SCAN): Selects single mode or scan mode as the A/D conversion operating
mode. See section 16.4, Operation, for single mode and scan mode operation. Only set the SCAN
bit while conversion is stopped (ADST = 0).
Bit 3—Channel Select 3 (CH3): Switches the analog input pins assigned to group 0 or group 1.
Setting CH3 to 1 enables AN8 to AN15 to be used instead of AN0 to AN7.
Bit 5
ADST
0
1
Bit 4
SCAN
0
1
Bit 3
CH3
0
1
Description
Description
Single mode
Scan mode
Description
AN8 to AN11 are group 0 analog input pins, AN12 to AN15 are group 1 analog input
pins
AN0 to AN3 are group 0 analog input pins, AN4 to AN7 are group 1 analog input pins
A/D conversion stopped
Single mode: A/D conversion is started. Cleared to 0 automatically when
Scan mode: A/D conversion is started. Conversion continues sequentially on the
conversion on the specified channel ends
selected channels until ADST is cleared to 0 by software, a reset, or
a transition to standby mode or module stop mode.
Rev. 5.00 Jan 10, 2006 page 595 of 1042
Section 16 A/D Converter
REJ09B0275-0500
(Initial value)
(Initial value)
(Initial value)