HD64F2623FA20J Renesas Electronics America, HD64F2623FA20J Datasheet - Page 480

IC H8S MCU FLASH 256K 100-QFP

HD64F2623FA20J

Manufacturer Part Number
HD64F2623FA20J
Description
IC H8S MCU FLASH 256K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2623FA20J

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
53
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2623FA20J
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F2623FA20J
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F2623FA20J
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD64F2623FA20JV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 13 Serial Communication Interface (SCI)
Clock
Either an internal clock generated by the on-chip baud rate generator or an external clock input at
the SCK pin can be selected as the SCI’s serial clock, according to the setting of the C/A bit in
SMR and the CKE1 and CKE0 bits in SCR. For details of SCI clock source selection, see table
13.9.
When an external clock is input at the SCK pin, the clock frequency should be 16 times the bit rate
used.
When the SCI is operated on an internal clock, the clock can be output from the SCK pin. The
frequency of the clock output in this case is equal to the bit rate, and the phase is such that the
rising edge of the clock is in the middle of the transmit data, as shown in figure 13.3.
0
D0
D1
D2
D3
D4
D5
D6
D7
0/1
1
1
1 frame
Figure 13.3 Relation between Output Clock and Transfer Data Phase
(Asynchronous Mode)
Data Transfer Operations
SCI initialization (asynchronous mode): Before transmitting and receiving data, you should first
clear the TE and RE bits in SCR to 0, then initialize the SCI as described below.
When the operating mode, transfer format, etc., is changed, the TE and RE bits must be cleared to
0 before making the change using the following procedure. When the TE bit is cleared to 0, the
TDRE flag is set to 1 and TSR is initialized. Note that clearing the RE bit to 0 does not change the
contents of the RDRF, PER, FER, and ORER flags, or the contents of RDR.
When an external clock is used the clock should not be stopped during operation, including
initialization, since operation is uncertain.
Figure 13.4 shows a sample SCI initialization flowchart.
Rev. 5.00 Jan 10, 2006 page 454 of 1042
REJ09B0275-0500

Related parts for HD64F2623FA20J