HD64F2623FA20J Renesas Electronics America, HD64F2623FA20J Datasheet - Page 508

IC H8S MCU FLASH 256K 100-QFP

HD64F2623FA20J

Manufacturer Part Number
HD64F2623FA20J
Description
IC H8S MCU FLASH 256K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2623FA20J

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
53
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2623FA20J
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F2623FA20J
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F2623FA20J
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD64F2623FA20JV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 13 Serial Communication Interface (SCI)
13.5
The following points should be noted when using the SCI.
Relation between Writes to TDR and the TDRE Flag
The TDRE flag in SSR is a status flag that indicates that transmit data has been transferred from
TDR to TSR. When the SCI transfers data from TDR to TSR, the TDRE flag is set to 1.
Data can be written to TDR regardless of the state of the TDRE flag. However, if new data is
written to TDR when the TDRE flag is cleared to 0, the data stored in TDR will be lost since it has
not yet been transferred to TSR. It is therefore essential to check that the TDRE flag is set to 1
before writing transmit data to TDR.
Operation when Multiple Receive Errors Occur Simultaneously
If a number of receive errors occur at the same time, the state of the status flags in SSR is as
shown in table 13.13. If there is an overrun error, data is not transferred from RSR to RDR, and
the receive data is lost.
Table 13.13 State of SSR Status Flags and Transfer of Receive Data
Notes:
Rev. 5.00 Jan 10, 2006 page 482 of 1042
REJ09B0275-0500
RDRF
1
0
0
1
1
0
1
X: Receive data is not transferred from RSR to RDR.
SSR Status Flags
Usage Notes
ORER
1
0
0
1
1
0
1
: Receive data is transferred from RSR to RDR.
FER
0
1
0
1
0
1
1
PER
0
0
1
0
1
1
1
Receive Data Transfer
RSR to RDR
X
X
X
X
Receive Error Status
Overrun error
Framing error
Parity error
Overrun error + framing error
Overrun error + parity error
Framing error + parity error
Overrun error + framing error +
parity error

Related parts for HD64F2623FA20J