S912XET256J2VAGR Freescale Semiconductor, S912XET256J2VAGR Datasheet - Page 555

no-image

S912XET256J2VAGR

Manufacturer Part Number
S912XET256J2VAGR
Description
16-bit Microcontrollers - MCU Watchdog OSC/Timer -40 C to + 105 C HCS12X MCU SPI
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S912XET256J2VAGR

Core
HCS12X
Data Bus Width
16 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
256 KB
Data Ram Size
16 KB
On-chip Adc
Yes
Package / Case
LQFP
Mounting Style
SMD/SMT
A/d Bit Size
12 bit
A/d Channels Available
24
Interface Type
CAN, SCI, SPI
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
119
Number Of Timers
25
Program Memory Type
Flash
Supply Voltage - Max
1.98 V, 2.9 V, 5.5 V
Supply Voltage - Min
1.72 V, 2.7 V, 3.13 V
All bits reset to zero.
14.3.2.21 ICPAR — Input Control Pulse Accumulators Register (ICPAR)
Read: Anytime
Write: Anytime.
All bits reset to zero.
The 8-bit pulse accumulators PAC3 and PAC2 can be enabled only if PAEN in PACTL is cleared. If PAEN
is set, PA3EN and PA2EN have no effect.
The 8-bit pulse accumulators PAC1 and PAC0 can be enabled only if PBEN in PBCTL is cleared. If PBEN
is set, PA1EN and PA0EN have no effect.
Freescale Semiconductor
Module Base + 0x0028
POLF[3:0]
PA[3:0]EN
Reset
MCZF
Field
Field
3:0
3:0
7
W
R
Modulus Counter Underflow Flag — The flag is set when the modulus down-counter reaches 0x0000.
The flag indicates when interrupt conditions have occurred. The flag can be cleared via the normal flag clearing
mechanism (writing a one to the flag) or via the fast flag clearing mechanism (Reference TFFCA bit in
Section 14.3.2.6, “Timer System Control Register 1
First Input Capture Polarity Status — These are read only bits. Writes to these bits have no effect.
Each status bit gives the polarity of the first edge which has caused an input capture to occur after capture latch
has been read.
Each POLFx corresponds to a timer PORTx input.
0 The first input capture has been caused by a falling edge.
1 The first input capture has been caused by a rising edge.
8-Bit Pulse Accumulator ‘x’ Enable
0 8-Bit Pulse Accumulator is disabled.
1 8-Bit Pulse Accumulator is enabled.
0
0
7
When TFFCA = 1, the flag cannot be cleared via the normal flag clearing
mechanism (writing a one to the flag). Reference
System Control Register 1
Figure 14-44. Input Control Pulse Accumulators Register (ICPAR)
= Unimplemented or Reserved
0
0
6
MC9S12XE-Family Reference Manual Rev. 1.25
Table 14-25. MCFLG Field Descriptions
Table 14-26. ICPAR Field Descriptions
0
0
5
(TSCR1)”.
NOTE
0
0
4
Description
Description
(TSCR1)”).
PA3EN
0
3
Chapter 14 Enhanced Capture Timer (ECT16B8CV3)
Section 14.3.2.6, “Timer
PA2EN
0
2
PA1EN
0
1
PA0EN
0
0
555

Related parts for S912XET256J2VAGR