SAM9M10 Atmel Corporation, SAM9M10 Datasheet - Page 253

no-image

SAM9M10

Manufacturer Part Number
SAM9M10
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9M10

Flash (kbytes)
0 Kbytes
Pin Count
324
Max. Operating Frequency
400 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
160
Ext Interrupts
160
Usb Transceiver
3
Usb Speed
Hi-Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
2
Uart
5
Lin
4
Ssc
2
Ethernet
1
Sd / Emmc
2
Graphic Lcd
Yes
Video Decoder
Yes
Camera Interface
Yes
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
440
Resistive Touch Screen
Yes
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
NO
External Bus Interface
2
Dram Memory
DDR2/LPDDR, SDRAM/LPSDR
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
0.9 to 1.1
Fpu
No
Mpu / Mmu
No / Yes
Timers
6
Output Compare Channels
6
Input Capture Channels
6
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
22.5.5
Figure 22-24. Trp and Trcd Timings
6355D–ATARM–7-Sep-11
6355D–ATARM–7-Sep-11
COMMAND
Multi-port Functionality
DQS[1:0]
SDCLK
BA[1:0]
DM1:0]
D[15:0]
A[12:0]
NOP
0
3
The SDRAM protocol imposes a check of timings prior to performing a read or a write access,
thus decreasing the performance of systems. An access to SDRAM is performed if banks and
rows are open (or active). To activate a row in a particular bank, it has to de-active the last open
row and open the new row. Two SDRAM commands must be performed to open a bank: Pre-
charge and Active command with respect to Trp timing. Before performing a read or write
command, Trcd timing must checked.
This operation represents a significative loss. (see
The multi-port controller has been designed to mask these timings and thus improve the band-
width of the system.
DDRSDRC is a multi-port controller since four masters can simultaneously reach the controller.
This feature improves the bandwidth of the system because it can detect four requests on the
AHB slave inputs and thus anticipate the commands that follow, PRECHARGE and ACTIVE
commands in bank X during current access in bank Y. This allows Trp and Trcd timings to be
masked (see
were already open. The best condition is met when the four masters work in different banks. In
the case of four simultaneous read accesses, when the four banks and associated rows are
open, the controller reads with a continuous flow and masks the cas latency for each different
access. To allow a continuous flow, the read command must be set at 2 or 3 cycles (cas latency)
before the end of current access. This requires that the scheme of arbitration changes since the
round-robin arbitration cannot be respected. If the controller anticipates a read access, and thus
before the end of current access a master with a high priority arises, then this master will not
serviced.
The arbitration mechanism reduces latency when conflicts occur, i.e., when two or more masters
try to access the SDRAM device at the same time.
PRCHG
NOP
Trp
4 cycles before performing a read command
Figure
ACT
22-25). In the best case, all accesses are done as if the banks and rows
NOP
Trcd
READ
BST
Latency =2
Figure
NOP
22-24).
Da Db
SAM9M10
SAM9M10
253
253

Related parts for SAM9M10