Sample Program Messages
SED1355
X23A-B-001-02
ERROR: Panel frame rate must be greater than zero
Select an appropriate panel frame rate as recommended in the panel specifications.
ERROR: Unable to save current settings
Could not save configuration values. The reason why is generally given before this message is
shown.
ERROR: Invalid clock frequency selected
The ClkI frequency is either too low or too high.
ERROR: Max. clock for 50ns FPM is unspecified
1355CFG does not support 50ns FPM-DRAM.
WARNING: Cannot set panel display mode
This message is shown if the configuration settings do not meet the hardware specifications, or if the
desired frame rate cannot be reached within 5%. See “Comments” on page 17 for more information.
WARNING: Cannot set simul display mode
This message is shown if the configuration settings do not meet the hardware specifications, or if the
desired frame rate cannot be reached within 5%. See “Comments” on page 17 for more information.
WARNING: Cannot set CRT display mode
This message is shown if the configuration settings do not meet the hardware specifications, or if the
desired frame rate cannot be reached within 5%. See “Comments” on page 17 for more information.
-PClk too slow to support 640 x 480
This message is shown after the “Cannot set ??? display mode” message. See “Comments” on page
17 to adjust the PClk.
-PClk too slow to support 800 x 600
This message is shown after the “Cannot set ??? display mode” message. See “Comments” on page
17 to adjust PClk.
Notice: Invalid clock selected for VESA frequencies. The monitor may
not sync!
This message is shown in the CRT Page when the PClk is not set to a standard VESA frequency. See
“Comments” on page 17 to adjust the PClk.
ERROR: Unknown HAL version.
When reading from or writing to a SED1355 utility, 1355CFG could not find the start of a valid
configuration table.
ERROR: Unable to open <filename>
Possible cause - no HAL information
1355CFG could not find the HAL configuration table.
ERROR: encountered while reading .S9 file.
The S9 file is corrupted.
ERROR: while attempting to write .S9 file.
The S9 file is corrupted.