mcf5407 Freescale Semiconductor, Inc, mcf5407 Datasheet - Page 79

no-image

mcf5407

Manufacturer Part Number
mcf5407
Description
Mcf5407 Coldfire Integrated Microprocessor User
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mcf5407AI162
Manufacturer:
FREESCALE
Quantity:
201
Part Number:
mcf5407AI162
Manufacturer:
FREESCAL
Quantity:
132
Part Number:
mcf5407AI162
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf5407AI162
Manufacturer:
ALTERA
0
Part Number:
mcf5407AI220
Manufacturer:
freescaie
Quantity:
6
Part Number:
mcf5407AI220
Manufacturer:
Freescale Semiconductor
Quantity:
135
Part Number:
mcf5407AI220
Manufacturer:
FREESCALE
Quantity:
1 831
Part Number:
mcf5407AI220
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf5407AI220
Manufacturer:
NXP
Quantity:
25
Part Number:
mcf5407CAI162
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
2.3 Integer Data Formats
Table 2-4 lists the integer operand data formats. Integer operands can reside in registers,
memory, or instructions. The operand size for each instruction is either explicitly encoded
in the instruction or implicitly defined by the instruction operation.
2.4 Organization of Data in Registers
The following sections describe data organization within the data, address, and control
registers.
2.4.1 Organization of Integer Data Formats in Registers
Figure 2-7 shows the integer format for data registers. Each integer data register is 32 bits
wide. Byte and word operands occupy the lower 8- and 16-bit portions of integer data
registers, respectively. Longword operands occupy the entire 32 bits of integer data
registers. A data register that is either a source or destination operand only uses or changes
the appropriate lower 8 or 16 bits in byte or word operations, respectively. The remaining
high-order portion does not change. The least significant bit (lsb) of all integer sizes is zero,
the most-significant bit (msb) of a longword integer is 31, the msb of a word integer is 15,
and the msb of a byte integer is 7.
The instruction set encodings do not allow the use of address registers for byte-sized
operands. When an address register is a source operand, either the low-order word or the
entire longword operand is used, depending on the operation size. Word-length source
msb
msb
31
31
31
31
Figure 2-7. Organization of Integer Data Formats in Data Registers
30
Not used
Not used
Table 2-4. Integer Data Formats
Bit
Byte integer
Word integer
Longword integer
Longword
Operand Data Format
Chapter 2. ColdFire Core
msb
15
msb Low order byte
7
Lower order word
1
16 bits
32 bits
8 bits
Size
lsb
lsb
lsb
lsb
1 bit
0
0
0
0
Bit (0 ≤ bit number ≤ 31)
Byte (8 bits)
Word (16 bits)
Longword (32 bits)
Integer Data Formats
2-13

Related parts for mcf5407