UPD70F3738GF-GAS-AX Renesas Electronics America, UPD70F3738GF-GAS-AX Datasheet - Page 854

no-image

UPD70F3738GF-GAS-AX

Manufacturer Part Number
UPD70F3738GF-GAS-AX
Description
MCU 32BIT V850ES/JX3-L 100-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Lr
Datasheet

Specifications of UPD70F3738GF-GAS-AX

Core Processor
RISC
Core Size
32-Bit
Speed
20MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
84
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
2.2 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3738GF-GAS-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
23.7.2 Releasing subclock operation mode
voltage detector (LVI), or clock monitor (CLM)) when the CK3 bit is set to 0.
clock by software, and set the CK3 bit to 0.
23.7.3 Releasing low-voltage subclock operation mode
that, transit to the normal mode according to 23.7.2 Releasing subclock operation mode. Be sure to follow this
procedure to transit the mode from the low-voltage subclock operation mode to the subclock operation mode.
852
The subclock operation mode is released by a reset signal (reset by RESET pin input, WDT2RES signal, low-
If the main clock is stopped (MCK bit = 1), set the MCK bit to 1, secure the oscillation stabilization time of the main
The normal operation mode is restored when the subclock operation mode is released.
Caution When manipulating the CK3 bit, do not change the set values of the CK2 to CK0 bits (using a bit
In low-voltage subclock mode, the subclock operation mode is set by setting the REGOVL0 register to 00H. After
(1) Procedure for setting “low-voltage subclock operation mode” → “subclock operation mode”
(2) If low-voltage subclock operation mode is released by reset
Make the following settings in the low-voltage subclock operation mode.
<1> • Disable the maskable interrupt by the DI instruction.
<2> Write C9H (enabling data) to the REGPR register.
<3> Write 00H to the REGOVL0 register (transit to the subclock operation mode).
<4> Write 00H (protection data) to the REGPR register.
<5> Wait for at least 800
<6> As necessary, enable the maskable interrupt, NMI interrupt, or INTWDT2 interrupt by the EI instruction
<7> Enable the DMA if necessary.
<8> Start the functions to be used, from among those that have been stopped in steps <1> and <2> in
Be sure to observe the above sequence.
Note, however, that <6>, <7>, and <8> may be performed at any time as long as it is done after <5>.
When the low-voltage subclock operation mode is released by a reset signal (reset by RESET pin input,
WDT2RES signal, low-voltage detector (LVI), or clock monitor (CLM)), the CPU shifts to the normal operation
mode immediately after the reset ends, and the REGOVL0 register is initialized to 00H and the REGPR
register to 00H (protection data). Be sure to secure the oscillation stabilization time that follows immediately
after a reset ends by setting the option byte.
• Disable the NMI interrupt (INTF02 = 0, INTR02 = 0).
• Create a status in which the INTWDT2 signal is not generated (create a status in which the INTWDT2
(restore the setting <1> above).
section 23.7.1 (1) Procedure for setting “subclock operation mode” → “low-voltage subclock
operation mode”.
manipulation instruction to manipulate the bit is recommended).
For details of the PCC register, see 6.3 (1) Processor clock control register (PCC).
signal is not generated immediately after watchdog timer 2 has been cleared).
μ
s by software.
CHAPTER 23 STANDBY FUNCTION
User’s Manual U18953EJ5V0UD
For details, see CHAPTER 29 OPTION BYTE.

Related parts for UPD70F3738GF-GAS-AX