TMP92CF26AXBG Toshiba, TMP92CF26AXBG Datasheet - Page 626

no-image

TMP92CF26AXBG

Manufacturer Part Number
TMP92CF26AXBG
Description
Microcontrollers (MCU) TLCS-900/H1 ROMLESS 144KB RAM
Manufacturer
Toshiba
Datasheet

Specifications of TMP92CF26AXBG

Processor Series
TLCS-900
Core
900/H
Data Bus Width
16 bit
Program Memory Type
ROM
Program Memory Size
8 KB
Data Ram Size
144 KB
Interface Type
I2C, I2S, UART, USB
Maximum Clock Frequency
80 MHz
Number Of Programmable I/os
136
Number Of Timers
10
Maximum Operating Temperature
+ 50 C
Mounting Style
SMD/SMT
Package / Case
FBGA-228
Development Tools By Supplier
BM1040R0A, BM1055R0B, SW96CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 6 Channel
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA
Quantity:
4 000
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Channel-fix
Single conversion
Channel-fix
Repeat conversion
Channel-scan
Single conversion
Channel-scan
Repeat conversion
Table 3.23.1 Interrupt Generation Timing and Flag Setting in Each AD Conversion Mode
Conversion mode
Note: EOS is cleared to “0” by reading this bit only.
(2)
ADMOD1<REPEAT, SCAN> are not involved.
ADMOD3<HADCH2:0> is performed only one time. When conversion ends, the
top-priority AD conversion end interrupt (INTADHP) is generated, which sets “1” in
ADMOD2<HEOS>. The HEOS flag is cleared to “0” only by being read.
d. Channel-scan repeat conversion mode
Top-priority AD conversion
The operation mode is only single conversion by channel-fix mode. The settings in
When startup conditions are established, a conversion at a channel specified by
conversion mode.
time after the conversion at a final channel ends, ADMOD0<EOS> is set to “1,”
generating Normal AD conversion End interrupt request. <EOS> is cleared to “0”
only by being read.
ADMOD1<REPEAT>. At the point when a scan conversion being executed ends,
the repeat conversion mode ends.
Mode or STOP Mode) immediately stops operation of the AD converter even if AD
conversion is still in progress. Therefore, ADC may consume current even if
operation is stopped, depending on stop condition of ADC that switches to standby
mode. For avoiding this problem, Stop ADC before switching to standby mode.
Setting ADMOD1<REPEAT, SCAN> to “11” selects the channel-scan repeat
This mode performs a conversion at selected scan channels repeatedly. Each
To stop the repeat conversion mode (mode of c and d) operation, write “0” in
Shift to a standby mode (IDLE2 Mode with ADMOD0<I2AD> = “0”, IDLE1
After conversion
end
Per one
conversion
Per four
conversions
After scan
conversion end
Each time after
one scan
conversion ends
Generation
Interrupt
Timing
92CF26A-625
EOS set timing
After conversion
end
Each time after
one conversion
ends
Each time after
four conversions
end
After scan
conversion end
Each time after
one scan
conversion ends
(Note)
ITM
0
1
REPEAT
ADMOD1
0
1
0
1
SCAN
TMP92CF26A
0
0
1
1
2007-11-21

Related parts for TMP92CF26AXBG