TMP92CF26AXBG Toshiba, TMP92CF26AXBG Datasheet - Page 326

no-image

TMP92CF26AXBG

Manufacturer Part Number
TMP92CF26AXBG
Description
Microcontrollers (MCU) TLCS-900/H1 ROMLESS 144KB RAM
Manufacturer
Toshiba
Datasheet

Specifications of TMP92CF26AXBG

Processor Series
TLCS-900
Core
900/H
Data Bus Width
16 bit
Program Memory Type
ROM
Program Memory Size
8 KB
Data Ram Size
144 KB
Interface Type
I2C, I2S, UART, USB
Maximum Clock Frequency
80 MHz
Number Of Programmable I/os
136
Number Of Timers
10
Maximum Operating Temperature
+ 50 C
Mounting Style
SMD/SMT
Package / Case
FBGA-228
Development Tools By Supplier
BM1040R0A, BM1055R0B, SW96CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 6 Channel
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA
Quantity:
4 000
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
(3) Serial clock generation circuit
(4) Receiving counter
(5) Receiving control
the pulses of the SIOCLK clock. It takes 16 SIOCLK pulses to receive 1 bit of data; each
data bit is sampled three times - on the 7th, 8th and 9th clock cycles.
The value of the data bit is determined from these three samples using the majority
rule.
For example, if the data bit is sampled respectively as 1, 0 and 1 on 7th, 8th and 9th
clock cycles, the received data bit is taken to be 1. A data bit sampled as 0, 0 and 1 is
taken to be 0.
This circuit generates the basic clock for transmitting and receiving data.
The receiving counter is a 4-bit binary counter used in UART Mode, which counts up
generated by dividing the output of the baud rate generator by 2, as described
previously.
In SCLK Input Mode with the setting SC0CR<IOC> = 1, the rising edge or falling
edge will be detected according to the setting of the SC0CR<SCLKS> register to
generate the basic clock.
clock, the internal clock f
external clock (SCLK0) is used to generate the basic clock SIOCLK.
sampled on the rising or falling edge of the shift clock which is output on the
SCLK0 pin, according to the SC0CR<SCLKS> setting.
In SCLK Input Mode with the setting SC0CR<IOC> = 1, the RXD0 signal is
sampled on the rising or falling edge of the SCLK0 input, according to the
SC0CR<SCLKS> setting
majority rule. Received bits are sampled three times; when two or more out of
three samples are 0, the bit is recognized as the start bit and the receiving
operation commences.
The values of the data bits that are received are also determined using the
majority rule.
• In I/O Interface Mode
• In UART Mode
• In I/O Interface Mode
• In UART Mode
In SCLK Output Mode with the setting SC0CR<IOC> = 0, the basic clock is
The SC0MOD0 <SC1:0> setting determines whether the baud rate generator
In SCLK Output Mode with the setting SC0CR<IOC> = 0, the RXD0 signal is
The receiving control block has a circuit, which detects a start bit using the
92CF26A-325
IO
, the match detect signal from timer TMRA0 or the
TMP92CF26A
2007-11-21