TMP92CF26AXBG Toshiba, TMP92CF26AXBG Datasheet - Page 624

no-image

TMP92CF26AXBG

Manufacturer Part Number
TMP92CF26AXBG
Description
Microcontrollers (MCU) TLCS-900/H1 ROMLESS 144KB RAM
Manufacturer
Toshiba
Datasheet

Specifications of TMP92CF26AXBG

Processor Series
TLCS-900
Core
900/H
Data Bus Width
16 bit
Program Memory Type
ROM
Program Memory Size
8 KB
Data Ram Size
144 KB
Interface Type
I2C, I2S, UART, USB
Maximum Clock Frequency
80 MHz
Number Of Programmable I/os
136
Number Of Timers
10
Maximum Operating Temperature
+ 50 C
Mounting Style
SMD/SMT
Package / Case
FBGA-228
Development Tools By Supplier
BM1040R0A, BM1055R0B, SW96CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 6 Channel
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA
Quantity:
4 000
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Note: It cannot overlap with three or more AD conversions.
Prohibition example 1: In FIRST normal AD conversion
Prohibition example 2: In FIRST normal AD conversion
→ (Before finished FIRST normal AD conversion) Started SECOND normal AD conversion
→ (Before finished SECOND normal AD conversion) Started THIRD normal AD conversion
→ (Before finished FIRST normal AD conversion) Started SECOND normal AD conversion
→ (Before finished SECOND normal AD conversion) Started THIRD high-priority AD conversion
to “0” only when read.
abort any ongoing conversion immediately, and restart.
hard ware trigger, normal AD conversion is restarted when start condition from hard
ware trigger is satisfied. When restart is set, normal AD conversion is aborted
immediately.
to ADMOD2<HADS> or a hard ware trigger occurs), the ADC aborts any ongoing
conversion immediately, and then start a Top-priority AD conversion for the channel
specified by ADMOD3<HADCH2:0>. Upon the completion of the Top-priority
conversion, the ADC stores the conversion result to ADREGSPH/L, and then resumes
the suspended normal conversion with that channel.
<HEOS> and <EOS> are set to “1” after conversion is completed. This flag is cleared
During a normal AD conversion, writing a “1” to ADMOD0<ADS> causes the ADC to
During a normal AD conversion, if normal AD conversion starting is enabled by
During a normal AD conversion, if a Top-priority AD conversion starts (writing a “1”
92CF26A-623
TMP92CF26A
2007-11-21

Related parts for TMP92CF26AXBG